Horizontal Terminations; Flex Vent 4" X 6-7/8 - Regency CV40E-NG Owners & Installation Manual

City series zero clearance direct vent gas fireplace
Table of Contents

Advertisement

Horizontal Terminations

"

Flex Vent 4" x 6-7/8

These venting systems, in combination with the CV40E/CB40E Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock
Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination
Locations" section.
Regency
®
Direct Vent (Flex) System Termination Kits includes all the parts needed to install the CV40E/CB40E using a lexible vent.
NOTE: A minimum of 1' (305mm) vertical off the top of the unit is required before any horizontal runs can start.
Contains:
FPI Kit #
Length
#946-513
2 Feet
1.
2.
3.
4.
#946-515
4 Feet
5.
6.
7.
8.
#946-516
10 Feet
9.
Notes:
1. Liner sections should be continuous without any
joints or seams.
2. Only Flex pipe purchased from Regency
used for Flex installations
3. Horizontal vent must be supported every 3 feet.
®
4. Regency
Direct Vent System (Flex) is only approved
for horizontal terminations.
5. Flex system can only be used up to a maximum
continuous vent length of up to 10 feet. If longer
runs are required, rigid pipe must be used.
6-7/8" lexible outer liner (Kit length)
4" lexible inner liner (Kit length)
spring spacers
thimble
AstroCap termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 1-1/2" drill point
®
may be
installation
City Series |
47