Regency CV40E-NG Owners & Installation Manual page 67

City series zero clearance direct vent gas fireplace
Table of Contents

Advertisement

11. Remove burner tray by lifting up and out.
CB40E shown
12. Loosen 4 screws in locations shown below (2 at front and 2 at rear)—slide burner
to the left away from the orifi ce and lift out.
front
screw locations
back screw locations
CB40E shown
13. Remove burner orifi ce with a 3/8" wrench. Use another wrench to hold
on to the elbow behind the orifi ce. Discard orifi ce Reinstall new burner
orifi ce LPG stamped #53 and tighten.
CV40E shown
14. Remove pilot retainer clip with pliers and pull off the pilot cap to expose
the pilot orifi ce.
Pilot retainer clip
Burner Orifi ce
Location
15. Unscrew the pilot orifi ce with the allen key; then replace with the LPG
pilot orifi ce and the pilot cap, provided in the kit.
16. Reinstall pilot cap and pilot retainer clip.
17. Prior to installing burner—adjust aerations settings - to 1/4" for LP.
Reinstall burner (see Step 13).
18. Ensure the pilot light is in the correct orientation to the Burner. Recon-
nect the gas and electrical supply to the appliance. Start the appliance.
(see section on Lighting Instructions) Ensure that pilot and burner igni-
tion is completed without delay. Check both your inlet and outlet pres-
sures at full load. With a soapy solution, leak test the entire system.
Verify both the correct fl ame and pilot appearance.
19. See Gas Pipe Pressure Testing in manual.
CV40E/CB40E
LP SYSTEM DATA
Min. Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifi ce Size
Maximum Input
Minimum Input
Altitude
Installer Notice:
These instructions must be left
with the appliance
installation
11" WC (2.73kpa)
10.5" WC (2.62 kpa)
2.9" WC (0.72 kpa)
#53 DMS
28,500 Btu/h (8.35 kW)
15,500 Btu/h (4.54 KW)
0-4500 ft (0-1372m)
.
City Series |
67