installation
Nailing strips CV40E
Nailing strips are shipped folded lat against the unit.
Fold nailing strips out 90º before installing unit.
Secure nailing strips to framing using wood or
metal screws.
Nailing strips CB40E
Nailing strips are shipped with the appliance and will
need to be attached. Note that the nailing strips are
not required if using the optional chase or extended
framing kit and may be recycled.
1. Secure nailing strip to appliance with 2 screws
per side.
2. Secure nailing strips to framing using wood or
metal screws.
Levelling bolts
There are four levelling bolts - two on each side
that can be adjusted if required.
Access panel removal
The front access panel may be removed for ease
of hooking up gas and electrical. Once complete
ensure that the access panel is reinstalled prior to
any inishing.
The CV40E has 4 screws to remove access cover
and the CB40E has 8 screws to remove access
cover. See locations in diagrams to the right.
12
| City Series
Nailing
strips
Nailing
strips
tooltip
4 screws
Levelling bolts
8 screws