How To Perform Zero Load Platform Overload Calibration; How To Replace The Platform Overload Load Cell - Genie S-45 XC Service And Repair Manual

Table of Contents

Advertisement

Service and Repair Manual
Platform Components
How to Perform Zero Load
Platform Calibration
Perform this procedure when the required weight
for full load calibration is not available. This
procedure will re-calibrate the zero load point
without affecting a previous full load calibration.
The platform load capacity will be reduced until a
full load calibration has been performed. A full load
calibration is required for rated load performance.
Note: Perform this procedure with the machine on
a firm, level surface.
Note: The turntable level sensor must be calibrated
before performing this procedure.
1
Fully retract the boom. Level the platform.
2
Remove all material, tools and equipment
from the platform. Remove the welder, if
equipped.
Tip-over hazard. Failure to
remove all factory and
non-factory accessories could
result in the machine tipping
over, causing death or serious
injury.
Enter Service Mode. Refer to Repair Procedure,
How to Enter the Service Mode.
3
Press the settings button above the display
and navigate to the Sensor Calibrations menu.
4
Navigate to the Load Sense calibration
screen.
5
Select and start the calibration procedure.
6
Follow the on-screen instructions to set the
zero load.
7
Continue to follow the prompts to accept the
weight.
8
The calibration is now complete.
Exit the Service Mode
40
S-40 XC • S-45 XC • S-40 TraX • S-45 TraX
How to R eplac e the Platform Ov erload Load C ell
How to Replace the Load Cell
Sensor
Note: The preload adjustment should only be
performed after the load cell sensor has been
replaced.
1
Remove all equipment or tools from the
platform. Remove the welder if equipped.
2
At the platform, remove the plastic instruction
holder from the document mount plate.
3
Tag and disconnect the load cell sensor
harness.
Illustration 1
1 flex plate
2 load cell sensor foot
3 jam nut
4 load cell sensor
4
Loosen the jam nut securing the load cell
sensor foot and rotate the foot screw
clockwise to remove the preload.
5
Remove the fasteners securing the load cell
sensor and remove the sensor.
Install the new Load Cell Sensor
6
Screw the foot with jam nut into the top of the
load cell sensor until the foot bolt extends out
of the bottom of the sensor.The foot should
not contact the flex plate when assembling
onto the platform support.
July 2019
Part No. 1286829GT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-40 traxS-40 xcS-45 trax

Table of Contents