Mitsubishi QD75P1N User Manual page 776

Q series
Table of Contents

Advertisement

APPENDICES
2. Select the test target axis.
Select the test target axis from the pull-down menu of "Target Axis".
3. Select the function.
Select "Positioning start signal" from the pull-down menu of "Select Function".
4. Perform positioning start test.
1) Select "Positioning Start Signal", "Block Start", or "Multiple Axes
Simultaneous Start" for "Start Type".
2) Set positioning start data according to the setting for "Start Type".
Positioning Start Signal: Set the positioning data No.
Block Start: Set the block No. and point No.
Multiple Axes Simultaneous Start: Set the multiple axes simultaneous
start data No.
Set "Step" and "External Command" as needed.
Step
To perform test operation by step start, check the "Start step" checkbox,
select a step mode from the pull-down list, and click the Continue button.
External Command
To enable external commands or control switch, select the corresponding
item and click the Set button.
3) Click the Starting button to perform test operation.
Appendix - 90
MELSEC-Q