Mitsubishi QD75P1N User Manual page 186

Q series
Table of Contents

Advertisement

5 DATA USED FOR POSITIONING CONTROL
Storage item
[Storage details]
[Reading the monitor value]
Buffer
memory
Md.3
Start
information
Md.4
The starting No. is stored.
Start No.
The starting time
Md.50
(year:month) is stored.
Start
(for the
(Year:month)
QD75P N/QD75D N only)
The following are stored.
Md.5
QD75P N/QD75D N:
the starting time (day:hour)
Start
QD75P /QD75D :
(Day:hour)
the starting time (hour)
Md.6
The starting time (minute:
Start
second) is stored.
(Minute:
second)
Note: If a start signal is issued against an operating axis, a record relating to this event may be output before a
record relating to an earlier start signal is output.
Storage details
This area stores the start information (restart flag, start origin, and start axis):
Restart flag: Indicates whether the operation has or has not been
Start origin : Indicates the source of the start signal.
Start axis : Indicates the started axis.
Monitoring is carried out with a hexadecimal display.
b15
b12
b8
0 0 0 0 0
Not used
Restart flag
Stored contents
Restart flag OFF
Restart flag ON
Monitoring is carried out with a hexadecimal display.
Buffer
memory
Monitoring is carried out with a hexadecimal display.
Monitoring is carried out with a hexadecimal display.
Monitoring is carried out with a hexadecimal display.
Reading the monitor value
halted and restarted.
b4
b0
Monitor
value
Start origin
Stored contents
Storage value
CPU module
00
External signal
01
Peripheral device
10
Storage value
0
1
A
B
C
b15
b12
b8
b4
A
B
C
Start No.
Stored contents
Positioning operation
JOG operation
Manual pulse generator
Machine OPR
Fast OPR
Current value changing
Simultaneous start
Buffer memory (stored with BCD code)
0
8
0
6
b15
b12
b8
b4
0 0 0 0 1 0 0 0 0 0 0 0 0 1 1 0
0 to 9
0 to 9
0 to 1 0 to 9
Buffer memory (stored with BCD code)
2
8
1
5
b15
b12
b8
b4
0 0 1 0 1 0 0 0 0 0 0 1 0 1 0 1
0 to 3
0 to 9
0 to 2
0 to 3
*1
*1: 00(not used) is stored for QD75P /QD75D .
Buffer memory (stored with BCD code)
4
9
0
7
b15
b12
b8
b4
b0
0
1 0 0 1 0 0 1 0 0 0 0 0 1 1 1
0 to 5
0 to 9
0 to 5
0 to 9
5 - 82
MELSEC-Q
Start axis
Stored contents
Axis 1
Axis 2
Axis 3
Axis 4
D
Monitor value
b0
A
B
D
Storage value
A
B
C
D
0
0
0
1
to
0
2
5
8
1
B
5
8
1
B
5
9
1
B
5
A
1
B
5
B
1
B
5
C
2
3
3
2
2
3
3
3
2
3
2
9
2
A
3
2
2
3
2
B
2
3
2
C
Monitor value
b0
0
8
0
6
00 to 99 (year) 00 to 12 (month)
Monitor value
b0
2
8
1
5
01 to 31 (day) 00 to 23 (hour)
*1
Monitor value
4
9
0
7
00 to 59 (minute)
00 to 59 (second)
Storage value
1
2
3
4
C
D
Reference
(Decimal)
001
600
7000
7001
7002
7003
7004
9010
9011
9001
9002
9003
9004

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents