9 MAJOR POSITIONING CONTROL
POINTS
(1) When the movement amount is converted to the actual number of output pulses, a fraction
appears after the decimal point, according to the movement amount per pulse. This fraction is
normally retained in the QD75 and reflected at the next positioning.
For the fixed-feed control, since the movement distance is maintained constant (= the output
number of pulses is maintained constant), the control is carried out after the fractional pulse is
cleared to zero at start.
Accumulation/cutoff for fractional pulses
When movement amount per pulse is 1.0 m and movement for 2.5 m is executed two times;
Conversion to output pulses: 2.5[ m]
Movement
amount
Output pulses
INC line1
Fixed-feed 1
(2) When the "reference axis speed" is set during 2-axis fixed-feed control, set so the major axis side
becomes the reference axis. If the minor axis side is set as the reference axis, the major axis side
speed may exceed the "
1.0 = 2.5 pulses
2.5 m
2 pulses
2 pulses
Pr.8
Speed limit value".
9 - 48
2.5 m
0.5 pulse hold by the QD75 is
carried to next positioning.
3 pulses (=2.5+0.5)
2 pulses
0.5 pulse hold by the QD75 is cleared to 0 at start
and not carried to next positioning.
MELSEC-Q