15 TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Refer to Section 5.3
"List of positioning data"
Refer to Section 5.3
"List of positioning data"
and Section 5.4
"Block start data"
Refer to Section 5.4
"Block start data"
Refer to Section 5.3
"List of positioning data"
Set range
(Setting with sequence program)
Same as in error codes 525.
Same as in error codes 504, 506.
<Special start instruction>
00
to 06
H
H
Correct the end address (positioning address).
(Refer to Section 9.2.10)
Correct the center point address (arc address).
(Refer to Section 9.2.11)
Correct the positioning address.
(Refer to Section 9.2.16, 9.2.17, 9.2.18)
In the error history, check the axis where the error
other than this error occurred, and remove the error
factor. Correct the block start data and positioning data.
Normalize the block start data.
Correct the special start instruction code.
(Refer to Section 5.4
Correct the control system.
(Refer to Section 5.3
15 - 27
MELSEC-Q
Remedy
)
Da.13
)
Da.2