5 DATA USED FOR POSITIONING CONTROL
Storage item
Md.24
Axis warning No.
Md.25
Valid M code
Md.26
Axis operation status
Md.27
Current speed
Whenever an axis warning is reported, a related warning code is stored.
This area stores the latest warning code always. (Whenever an axis warning is
reported, a new warning code replaces the stored warning code.)
Cd.5
When the "
Axis error reset" (axis control data) is set to ON, the axis
warning No. is cleared to "0".
This area stores an M code that is currently active (i.e. set to the positioning data
relating to the current operation).
Update timing
: turning ON of the M code ON signal
When the PLC READY signal (Y0) goes OFF, the value is set to "0".
This area stores the axis operation status.
Da.8
"
Command speed" of the positioning data currently in execution is stored.
Da.8
If "
Command speed" is set to "-1", this area stores the command speed
set by the positioning data used one step earlier.
Da.8
If "
Command speed" is set to a value other than "-1", this area stores the
command speed set by the current positioning data.
If the speed change function is executed, "
(For details of the speed change function, refer to Section 12.5.1.)
5 - 92
Storage details
Cd.14
New speed value" is stored.
MELSEC-Q