5 DATA USED FOR POSITIONING CONTROL
Setting item
Cd.16
Inching movement amount
Cd.17
JOG speed
Cd.18
Continuous operation
interrupt request
•
Use this data item to set the amount of movement by inching.
•
The machine performs a JOG operation if "0" is set.
•
Set a value within the following range:
mm
Pr.1
-1
( × 10
µm)
Unit setting
Setting range
0 to 65535
•
Use this data item to set the JOG speed.
•
Set a value within the following range:
mm
Pr.1
-2
×
(
10
mm/min)
Unit setting
Setting
0 to
range
2000000000
•
To interrupt a continuous operation, set "1" to this data item.
•
After processing the interruption request ("1"), the QD75 automatically resets the
value to "0".
5 - 116
Setting details
inch
degree
-5
( × 10
( × 10
inch)
0 to 65535
0 to 65535
inch
degree
-3
-3
×
×
(
10
inch/min)
(
10
degree/min)
0 to
0 to
2000000000
2000000000
MELSEC-Q
pulse
-5
degree)
(pulse)
0 to 65535
pulse
(pulse/s)
[QD75P N/QD75D N]
0 to 4000000
[QD75P /QD75D ]
0 to 1000000