4 INSTALLATION, WIRING AND MAINTENANCE OF THE PRODUCT

4.3.2 Wiring of the differential driver common terminal

Applicable connectors
Wire diameter
0.24 to 2.5mm
(24 to 12AWG)
Wiring example
Module front
Insert until hook
catches.
When the differential driver output system (QD75D N/QD75D ) is used, a potential
difference between commons may occur between the differential driver common
terminal and the differential receiver common terminal of the drive unit. To remove the
potential difference between commons, connect the differential driver common terminal
of the QD75D N/QD75D
unit.
When the common terminal of the drive unit is photocoupler-connected, the wiring to
the differential driver common terminal of the QD75D N/QD75D
since a potential difference between commons does not exist.
(For the drive unit specifications, refer to the manual of the used drive unit.)
To wire the differential driver common terminal, use the wire applied to the following
table.
Type
2
Stranded wire/single wire
The following shows an example of wiring to the differential driver common terminal of
the QD75D N/QD75D .
Up to two cables can be connected to one differential driver common terminal. (For
details, refer to Section 3.1 "Performance specifications".
Module bottom
To differential receiver common terminal of drive unit
Module bottom
and the differential receiver common terminal of the drive
Material
Copper
Differential driver common terminal
Module side
4 - 14
MELSEC-Q
is not needed
Temperature rating
75˚C or more
Module front