9-13

Valve Coils

How to Test a Coil
A properly functioning coil provides an
electromotive force which operates the solenoid
valve. Critical to normal operation is continuity
within the coil that provides this force field.
Electrocution hazard. Contact with
electrically charged circuits could
result in death or serious injury.
Remove all rings, watches and
other jewelry.
1 Tag and disconnect the wire harness from the
coil to be tested.
2 Test the coil resistance.
Result: The resistance should be within
specification, plus or minus 30%.
Result: If the resistance is not within
specification, plus or minus 30%, replace the
coil.
Valve Coil Resistance
Description
Proportional valve, 12V DC
(schematic items AB, AC, CA and DA)
Proportional valve
12V DC (engine models) .................................... 4 to 6Ω
24V DC (DC models) ...................................... 18 to 21Ω
(schematic items BA and BB)
Solenoid valve, 2 position 2 way
10V DC (schematic item JD)
Solenoid valve, 2 position 2 way
10V DC (engine models) .................................... 6 to 8Ω
20V DC (DC models) ...................................... 26 to 28Ω
(schematic item KD)
Part No. 65162
Valve Coil Resistance
Description
Solenoid valve, 2 position 3 way
10V DC (engine models) (schematic item BD)
Solenoid valve, 2 position 3 way
20V DC (DC models) (schematic item BD)
Solenoid valve, 2 position 3 way
10V DC (schematic items ED, EE,
FE, FF, EI, GD and GI)
Solenoid valve, 2 position 3 way
10V DC (schematic item FJ)
Solenoid valve, 2 position 3 way
20V DC (schematic item HE)
Solenoid valve, 2 position 3 way
20V DC (schematic item HJ)
Solenoid valve, 3 position 4 way, 10V DC
(schematic items EF, EG, EH, EL,
EM, EO, FG, FH, FI, FM, FN and FP)
Solenoid valve, 3 position 4 way
20V DC (schematic items HM and HN)
Solenoid valve, 3 position 4 way
Specification
10V DC (schematic items JB and JC)
4 to 6Ω
Solenoid valve, 3 position 4 way
10V DC (engine models) .................................... 4 to 6Ω
20V DC (DC models) ...................................... 18 to 20Ω
(schematic items KB and KC)
Solenoid valve, 2 position 3 way
10V DC with manual over ride (schematic item GE)
6 to 8Ω
Solenoid valve, 2 position 3 way
20V DC with manual over ride (schematic item HF)
Solenoid valve, 3 position 4 way
10V DC with manual over ride
(schematic items GF, GG, GH and GO)
Solenoid valve, 3 position 4 way
20V DC with manual over ride
(schematic items HG, HH, HI and HP)
TMZ-50/30
Section 4 • Repair Procedures
MANIFOLDS
Specification
6 to 8Ω
26 to 28Ω
6 to 8Ω
4 to 6Ω
26 to 28Ω
18 to 20Ω
6 to 8Ω
26 to 28Ω
4 to 6Ω
6 to 8Ω
26 to 28Ω
6 to 8Ω
26 to 28Ω