Figure 4: User Group 122 Example - Bosch D7212GV3 Program Entry Manual

Table of Contents

Advertisement

D7212GV3 | Program Entry Guide | 3.0

Figure 4: User Group 122 Example

Master User:
ID 122.
1
 CRD ID 122-0
 Sub User -1: ID 122-1
CRD ID 122-1
2
 Sub User -2: ID 122-2.
CRD ID 122-2
 Sub User -3: ID 122-3.
CRD ID 122-3
1 - User passcode
2 - User token or card
In reporting systems using Phone # Format, all three digits of the User ID Code are transmitted to
the central station with appropriate reports. Central station automation computer systems can
accept only Zonex and Comex style User IDs. Refer to Point/User Flag in Section 2.1 Phone on
page 8.
User ###
Default:
001
Selection:
000 or 001 to 099
Enter the User number you are programming.
User 000 is the Service Authority Level
(Level 15). You cannot change the
programming for user 000.
Only the Service Authority Level (User
000) can delete User 000. When a user
other than User 000 tries to delete the
passcode for User 000, the keypad
displays NOT IN USE.
User 000 cannot be added or changed at
the keypad whether it exists or not.
U### Passcode
Default:
Refer to the program record sheet
Selection:
Three to six digits ( 0 to 9)
Enter three to six digits to enable a passcode for the
master user in this group.
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Passcodes, Access Credentials, and User Groups
User I.D.000 is the reserved user for
service personnel. The default service
passcode is 123.
The programmer does not allow you to
enter any passcode number that might
conflict with a duress passcode. The
programmer reserves the passcode
number plus 1, passcode number plus 2,
passcode-number minus 1, and passcode
number minus 2.
For example, when a passcode of
654321 is entered, 654322, 654323,
654320, and 654329 are reserved and
are not available to other users.
The authority to silence a bell is granted
to all passcodes regardless of their
authority level assignments. A user
passcode can silence a Fire or Burg bell
as long as any authority level is assigned
to the area where the bell can be
silenced.