This item determines how often the default status
information is sent to the serial interface module
(SIM). The status information includes:
The current point status (normal or off-
normal),
The control panel's area status (Master
Armed, Master Instant Armed, Perimeter
Delay Armed, Perimeter Instant Armed,
Disarmed, Area Entry Delay, Perimeter Entry
Delay, Area Exit Delay, and Perimeter Exit
Delay)
The control panel status (AC Fail, Battery
Missing, AC Restore, Battery Low, and so
on)
Relay status (relay on or relay off)
Entries are in 100 msec increments. If a 5 is entered,
the status information is sent every 500 msec (or 0.5
sec). An entry of 10 equals 1 sec.
6.5

SDI RPS Parameters

Configure remote programming software (RPS)
parameters when communicating over a private local-
area network (LAN), wide-area network (WAN), or
general packet radio system (GPRS). To allow RPS
to communicate with a control panel over a LAN or
WAN, an SDI-Ethernet two-way network interface
module (NIM) and RPS are required. (The latest
version of RPS is recommended.) The computer on
which RPS is installed needs a network card. See
your information systems administrator for network
requirements.
This section allows you to:
Define the RPS parameters necessary to
communicate by an external modem that can
be connected to a D9133DC Direct Connect
Programming Module.
Provide for local programming by a D4010i or
D9133DC Serial Interface Module.
Provide remote programming by a Conettix
DX4020 or D9133TTL-E Ethernet Network
Interface Module.
Provide enhanced route paths for event
reporting through a network using a Conettix
DX4020 Ethernet Network Interface Module.
Although not listed in this section, RPS checks for the
RPS passcode (refer to Section 2.6 RPS Parameters
on page 26), Datalock Code, and control panel type
to determine if this RPS session should continue.
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
AUXPARM
The RPS via Phone? prompt (Figure 6
on page 114), if selected, contacts RPS
by the control panel phone line and not
the external modem. Users cannot start
an RPS session by the external modem.
If you are using an external modem, RPS
sessions can be started only by
programming Answer Armed and Answer
Disarmed (to a value greater than 0) or
by setting RPS Line Monitor to Yes.
6.5.1

Configuration for RPS over Network

COMMAND 43 (Remote Programming) can establish
communication with RPS over the phone or over the
network. Figure 6 on page 21 shows the structure of
COMMAND 43.
Answer RPS Over Network
Default:
Selection:
Yes
No
This prompt determines if the control panel
automatically answers RPS-initiated sessions
through a network interface module on the SDI bus.
This prompt can be momentarily disabled by
selecting ALLOW ANSWER through COMMAND 43
(Remote Programming) menu (refer to Figure 6 on
page 114 and Figure 7 on page 115).
If the Reset switch (labeled S1) label is in
the locked position, network RPS
programming is allowed even if this
prompt is set to No.
RPS Address Verification
Default:
Selection:
Yes
No
Yes
Yes or No
Enable automatic answer of
RPS-initiated sessions over the
network.
Do not automatically answer
RPS-initiated sessions over the
network.
No
Yes or No
Verifies that the incoming RPS IP
address matches the address
entered in RPS IP Address.
Do not verify the RPS IP address.
Allow RPS to connect to the control
panel from any network source.