Table 21: Keypad Programming Choices - Bosch D7212GV3 Program Entry Manual

Table of Contents

Advertisement

D7212GV3 | Program Entry Guide | 2.0

Table 21: Keypad Programming Choices

Selection
Description
Blank
Disable the function panel-wide.
The keypad shows NO
AUTHORITY if you access the
function using a command or the
Function List.
E
Enable the function panel-wide.
The function can be executed
without entering a passcode.
P
Passcode required. When the
passcode is entered at the
keypad, the control panel checks
the user's authority level. Refer to
Section 2.10.6 Authority Level
Selections on page 61.
Refer to Section 2.10.6 Authority Level
Selections on page 61 for a detailed
description of the functions on the
following pages. These parameters
determine only if the authority level
functions are passcode protected.
Master Arm Delay
Default:
P
Selection:
-, E, or P
P
Passcode: Required for all users
with Master Arm Delay enabled for
their authority level.
E
Enable: A user does not need a
passcode to use [COMMAND][1].
-
Disable Master Arm Delay cannot be
accessed in the function menu or
started with a command even if this
function is enabled for the user's
authority level.
Function
Function Name
No.
2
Master Arm Delay
Use this arming function to master arm disarmed
areas. If enabled, the following arming choices are
available to the user with this authority.
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Panel and Area Wide Parameters
Master Arm Instant
Use this arming function to master arm instant areas
that are disarmed. Entry and exit delays are not
provided with this arming function. This causes a
Perimeter and Interior Delay point to act as an Instant
point.
For SIA CP-01 Compliance
Perimeter Instant
Instant arms all perimeter points with point response
that starts an instant alarm (refer to P## Point
Response in Section 4.2 Point Responses on page
81) in the area where the keypad is assigned. Entry
and exit delays are not provided with this arming
function. This function causes a Perimeter Delay
point to act as a Perimeter Instant point.
For SIA CP-01 Compliance
Perimeter Delay
Alternate
Keystroke
[COMMAND][1]
Default:
- (Disabled)
Selection:
-, E, or P
Function
Function Name
No.
3
Master Arm
Instant
This feature is not allowed in SIA CP-01
compliant installations.
Default:
- (Disabled)
Selection:
-, E, or P
Function
Function Name
No.
4
Perimeter Instant
Arm
This feature is not allowed in SIA CP-01
compliant installations.
Default:
P
Selection:
-, E, or P
Function
Function Name
No.
5
Perimeter Delay
Arm
EN | 55
Alternate
Keystroke
[COMMAND][1][1]
Alternate
Keystroke
[COMMAND][2]
Alternate
Keystroke
[COMMAND][3]