A# Entry Warning
Default:
Yes
Selection:
Yes or No
Yes
Pulse the alarm output for the last 10
sec of the Entry Delay time.
No
Do not pulse the Alarm Bell output
during the Entry Delay time.
When enabled, the Alarm Bell output pulses on and
off every 2 sec for the remaining 10 sec of the Entry
Delay time.
For SIA CP-01 Compliance
A# Entry Warning must be set to Yes.
2.9

Keypad (Command Center)

This section contains three programming categories:
Cmd Cntr Assignment, Area Text, and Custom
Function.
2.9.1

Keypad (Command Center) Assignment

This programming category assigns a keypad to an
area and determines if the keypad is supervised. The
keypads are connected to the control panel using a
two-wire serial data interface (SDI) bus.
This bus can support up to eight supervised keypads,
each with its own unique keypad address (CC) and
corresponding DIP switch address settings. If the
keypads are not supervised, you can install multiple
keypads with the same DIP switch address setting for
up to 32 unsupervised keypads.
Enhanced keypads (D1260 Series) and standard
keypads (D1255 Series) cannot share the same SDI
Address.