D9412GV2/D7412GV2
Program Entry Guide
EN
Control Panels

Advertisement

Table of Contents
loading

Summary of Contents for Bosch D9412GV2

  • Page 1 D9412GV2/D7412GV2 Program Entry Guide Control Panels...
  • Page 2 D9412GV2/D7412GV2 | Program Entry Guide | EN | 2 Tips, Notes, Cautions and Warnings Trademarks Throughout this document helpful tips and notes are presented concerning the entire application or ® CoBox is a registered trademark of Lantronix programming the unit. They are displayed as follows: ®...
  • Page 3: Table Of Contents

    D9412GV2/D7412GV2 | Program Entry Guide | Table of Contents EN | 3 2.11.2 Keypad Selections ..........54 Table of Contents 2.11.3 Access Control Functions........ 57 2.11.4 Authority Level Selections ......61 Introduction............5 2.11.5 Access Control Levels ........69 Using this Program Entry Guide ......5 2.12...
  • Page 4 D9412GV2/D7412GV2 | Program Entry Guide | Table of Contents EN | 4 Cross Point Parameters ........132 Table 19: Event Descriptions, Priorities, and Numbers ............ 23 RADXAXS .............135 Table 20: Programming Four-Digit Account Door Profile.............135 Numbers ............ 32 Strike Profile............138 Table 21: Programming Ten Digit Account Event Profile............139...
  • Page 5: 1.0 Introduction

    EN | 5 Table 2: Literature Referenced 1.0 Introduction Using this Program Entry Guide Document Name Part Number This guide is only for programming the D9412GV2 1. D1255 Installation Instructions 74-06819-000 and D7412GV2 Control Panels. 2. D1256/D1257 Installation 74-06925-000 Although this guide specifically refers to the...
  • Page 6: Product Handlers

    D9412GV2/D7412GV2 | Program Entry Guide | 1.0 Introduction EN | 6 Product Handlers Programming the 9000GV2 Series requires multiple product handlers. The availability of each handler is indicated in Table 3. Refer to the specific control panel’s release notes to determine the most current handler versions.
  • Page 7: Guide To Programming Options

    D9412GV2/D7412GV2 | Program Entry Guide | 1.0 Introduction EN | 7 Guide to Programming Options Programming the Control Panel with the D5200 Programmer This guide is set up in a specific order. Related program entries are grouped together in modules as Caution: Do not connect the D5200 to they appear in the specific product handlers.
  • Page 8 D9412GV2/D7412GV2 | Program Entry Guide | 1.0 Introduction EN | 8 Notes: Bosch Security Systems | 5/05 | F001U003636B...
  • Page 9: 2.0 Gv2Main

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 9 The control panel is programmed with a seven-second dial tone detect period. When a dial tone is detected or 2.0 GV2MAIN the waiting period ends, the control panel begins to Use GV2MAIN programming module to define the dial.
  • Page 10: Phone Parameters

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 10 Phone Parameters Point/User Flag The program items in this category describe panel-wide Default: characteristics for telephone dialing, receiver format, and supervision. Selection: Yes or No Modem Format The control panel sends a flag with...
  • Page 11: Table 5: Modem Iiia

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 11 D6000: Opening/Closing User ID numbers are identified at the receiver as ZONEs (same identification Table 5: Modem IIIa Communication Format Data - User ID Numbers as independent points). Table 7: Zones...
  • Page 12: Phone Supv Time

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 12 Phone Supv Time Buzz on Fail Default: Blank Default: Selection: Selection: Blank or 10 to 240 Yes or No Blank No phone line supervision. Generate panel-wide trouble tones and...
  • Page 13: Routing

    Enhanced Routing party must go on hook (hang up) for a fixed interval The D9412GV2 and D7412GV2 allow events to be before a dial tone is available for a new call. This sent to up to four additional SDI Paths. The network interval varies with telephone company equipment.
  • Page 14: Routing Destination Communication Failures

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 14 2.3.6 Routing Destination Communication Route # Failures When the R# Primary Device fails to connect with Default: the central station after one or two attempts (refer to Selection: 1 to 4...
  • Page 15: Table 8: Diagnostic Reports

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 15 Fire Reports R# Backup Device Selecting Yes enables a report to be sent when the Default: Blank event occurs. Selection: Blank, 1 to 4 Table 8: Diagnostic Reports Phone 1 or SDI Path 1 is this group’s backup destination if the primary destination fails.
  • Page 16: Table 9: Burglar Reports

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 16 Restoral Reports are not sent if the Burglar Reports control panel resets after a point is Select Yes to send a report when the event occurs. bypassed and then unbypassed. This is true for both Fire and Non-fire points.
  • Page 17: Table 11: Test Reports

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 17 Test Reports Table 11: Test Reports R# Test Report To send a single Test Report ( enable Sked Function Code #9 (Test Report) in the Report Selections Report Description Skeds section of the program.
  • Page 18: Table 12: Diagnostic Reports

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 18 Enable Rt Comm Fail and Rt Comm Table 12: Diagnostic Reports Restore in only one route group. Report Selections Report Description Enable Rt Comm Fail and Rt Comm R# SDI Dev...
  • Page 19: Table 15: Rps Reports

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 19 RPS Reports Point Reports Selecting Yes enables sending a report when the RPS Selecting Yes enables a report to be sent when the Passcode Event occurs. event occurs. RPS Access Fail can indicate a...
  • Page 20: Table 17: User Change Reports

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 20 User Chng Reports Access Reports Selecting Yes enables a report to be sent when the Selecting Yes enables a report to be sent when the event occurs. event occurs.
  • Page 21: Enhanced Routing

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 21 For example, if you want to send events using Route Enhanced Routing Group 1 over a LAN or WAN as your primary Enhanced routing allows the control panels to...
  • Page 22: Figure 1: Pager Display Fields

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 22 Numeric Pager Capability If the External Modem feature is used, RG# Primary SDI and RG# Backup SDI The D9412GV2 and D7412GV2 Control Panels can must be set to No. The control panel send most events to a numeric pager.
  • Page 23: Event Descriptions, Priorities, And Numbers

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 23 For example, the phone number 2773074***CC (seven Programming the Pager Phone Number digit pager phone number followed by three asterisks To program the pager phone number, enter the and two pauses) produces the following pager display: number used to reach the pager, followed by pauses.
  • Page 24 D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 24 Table 19: Event Descriptions, Priorities, and Table 19: Event Descriptions, Priorities, and Numbers, continued Numbers, continued Event Event Event Event Event Description Priority Number Event Description Priority Number Parameters Changed...
  • Page 25: Power Supervision

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 25 Power Supervision • 9 (such as 9, 19, 29, 39, and so on): The AC Fail Time interval is in minutes and an AC Fail Event AC Fail Time is sent after the loss of AC for this amount of time.
  • Page 26: Ac Fail/Res Rpt

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 26 AC/Battery Buzz To eliminate AC Reporting, AC Tag Along and AC Fail/Res Rpt must be programmed Default: as No and the second digit of the AC Fail Time must be a 1, 2, 3, 4, 5, or 6.
  • Page 27: Printer Parameters

    Printer Parameters P## Scope Up to three D9131A Parallel Printer Interface Modules Default: No Printer can be connected to the D9412GV2’s (one printer for Selection: No Printer, Area, Account, Panel the D7412GV2’s) SDI bus. Each printer is identified Wide, Custom by an address of 17, 18, or 19.
  • Page 28: Rps Parameters

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 28 P## Point Event P## Fire Events Default: Refer to the program record sheet Default: Refer to the program record sheet Selection: Yes or No Selection: Yes or No All events in this group print at P## Usr Chng Evt assigned printer.
  • Page 29: Log Threshold Reports

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 29 2.7.2 Log Threshold Reports Log % Full If communication with RPS is unsuccessful, or if no phone number is programmed in RPS Ph , the control Default: Blank panel generates Log Threshold and Bad Call to Ram.
  • Page 30: Rps Call Back

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 30 RPS Call Back Program this item No if it causes false seizures of the phone line or if you do not Default: use RPS. This indicates that a device...
  • Page 31: Miscellaneous

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 31 Miscellaneous RPS Ph Default: Blank Duress Type Selection: Blank or up to 24 characters Default: Blank Control panel does not dial a phone Selection: 1 or 2 number for RPS.
  • Page 32: Area Parameters

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 32 A# Acct Number Cancel Report Default: 0000 Default: Selection: For BFSK: 0000 to 0999, Selection: Yes or No 0BBB to 0FFF Send Cancel and Fire Cancel Reports For Modem (four-digit account according to routing.
  • Page 33: Figure 2: Account Number Entry

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 33 Although the D5200 allows the character Figure 2: Account Number Entry “A” to be entered into the account, do not use this character for the account number. Any account number digits containing “A”...
  • Page 34: A# Exit Tone

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 34 • Do not enable the Cross Point feature A# Exit Tone in point indexes designated for Fire points. Default: • Selection: Check with your authority having Yes or No...
  • Page 35: Verify Time

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 35 Table 22: Verify Time Verification Point Verify Time/Reset 60 second Restart Alarm Verification Cycle if Activiation Sensors Confirmation an Alarm Power removed, Generate alarm if Verification point additional activity ignore activity activates.
  • Page 36: A# Area Type

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 36 A# Area Type Default: Regular Selection: Regular, Master, Associate, or Shared Regular Arms or disarms as an independent area. Master Does not allow arming for this area unless all associate areas with the same A# account number are master exit delay armed or master armed.
  • Page 37: Shared-Area Characteristics

    If a point is faulted in the shared area, CHK AREA appears on the associate keypad that is arming the last The D9412GV2 and the D7412GV2 have two main associate area. Associate area keypads can show faults types of annunciation: Fire Bell and Burg Bell. Both...
  • Page 38: Area

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 38 Select the bell pattern this area uses to signal an alarm on a Fire point. Area Press the [Space] bar to scroll through the selections. Default: Press [Enter] when the correct selection appears in the...
  • Page 39: Open/Close Options

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 39 Bell Test After Confirmation A# Single Ring In areas that send Opening and Closing Reports, the Default: Bell Test occurs after the control panel sends the Closing Report and receives an acknowledgment from...
  • Page 40: Area

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 40 To suppress reports: Area • Use Opening/Closing Windows to suppress Default: reports for a specified period of time and then automatically turn them on again. Selection: 1 to 8 •...
  • Page 41: A# Area O/C

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 41 Determines if opening and closing activity is reported A# Area O/C when it occurs inside an Opening or Closing Window, as programmed in O/C Windows. Default: Reports are always logged and printed on a local...
  • Page 42: A# Fail To Close

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 42 A# Fail to Close A# Restrictd O/C Default: Default: Selection: Yes or No Selection: Yes or No Fail to Close Report is sent for this Restrict Opening and Closing Reports...
  • Page 43: Arming Features

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 43 • To suppress reports immediately after midnight, A# Perimeter O/C use another window (for example, 00:01 start to 02:00 stop). Default: 2.9.6 Arming Features Selection: Yes or No A# Two Man Rule This area can send Perimeter Opening and Closing Reports.
  • Page 44: A# Early Ambush

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 44 D1255 Keypad When the first digit of the second code is pressed, the following message appears. As each digit is pressed, an After the first valid passcode is entered, the D1255 additional asterisk appears.
  • Page 45: Keypad

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 45 2.10 Keypad (Command Center) Parameter Setup Requirement: The Early Ambush timer can be started and stopped This programming module contains three only by pass codes with the L## Passcode Disarm programming categories: Cmd Cntr Assignment, Area authority.
  • Page 46: Cc# Supervised

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 46 CC# Supervised CC# Scope Default: Refer to the program record sheet Default: Refer to the program record sheet Selection: Selection: Yes or No Panel Wide, Custom, No Keypad, Area, and Account Only one keypad can be installed for this CC SDI address.
  • Page 47: Cc# A1[Through A8] In Scope

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 47 CC# A1[through A8] in Scope CC# Entr Cycl Dr Default: Refer to the preceding important Default: note Selection: Yes or No Selection: Yes or No The [ENTER] key is used to cycle the...
  • Page 48: Cc# Assign Door

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 48 CC# Trouble Tone CC# Assign Door Default: Default: Blank Selection: Selection: Yes or No 1 to 8, Blank Panel-wide trouble tones sound and Blank No door controller is assigned for adding visual displays show at this keypad.
  • Page 49: Cc# Exit Tone

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 49 CC# Exit Tone CC# Close Door Default: Default: Selection: Selection: Yes or No Yes or No This keypad sounds entry tones. This keypad sounds a tone and displays CLOSE DOOR #.
  • Page 50: 2.10.2 Area Text

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 50 CC# Passcode Follows Scope CC# Menu Key Lock Default: Default: Selection: Selection: Yes or No Yes or No Master Arming allows a user to change If set to Yes, the user is prompted to...
  • Page 51: Area

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 51 Blank Entry Area A blank entry disables the ACCT IS ON display for Default: this area. An account wide area shows the AREA # IS ON text instead of the ACCT IS ON text.
  • Page 52: Cf### Key Strokes

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 52 2.10.3 Custom Function CF### Key Strokes Use custom functions to simplify complex keystroke sequences entered at the keypad. These items are Table 23: CF### Key Strokes similar to speed dialing on a telephone. When the...
  • Page 53: D1260 Keypad

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 53 If a command within the Custom Function Figure 3: Softkey Locations on the D1260 Keypad is pass-code protected, ENTER PASSCODE appears at the keypad. The user must enter a valid pass code must be entered before proceeding with the rest of the Custom Function.
  • Page 54: User Interface

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 54 Custom function cannot be used to change 2.11 User Interface time (such as Daylight Saving Time). Use Define which functions can be used by each of the Skeds S## Function Codes 13 and 14 to fourteen user authority levels.
  • Page 55: Keypad Programming Choices

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 55 Mstr Arm Inst Table 25: Keypad Programming Choices Default: Blank Selection Description Selection: Blank, E, or P Blank Disable the function panel-wide. Function No. Function Name Alternate Keystroke The keypad shows NO...
  • Page 56: Watch Mode

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 56 Watch Mode View Area Stat Default: Default: Selection: Selection: Blank, E, or P Blank, E, or P Function No. Function Name Alternate Keystroke Function No. Function Name Alternate Keystroke...
  • Page 57: Access Control Functions

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 57 Fire Test Access Ctl Level Default: Default: Selection: Blank, E, or P Selection: Blank, E, or P Function No. Function Name Alternate Keystroke Function No. Function Name Alternate Keystroke...
  • Page 58: Chg Passcode

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 58 Extend Close Chg Passcode Default: Default: Selection: Blank, E, or P Selection: Blank, E, or P Function No. Function Name Alternate Keystroke Function No. Function Name Alternate Keystroke Extend Close...
  • Page 59: User Cmd 9

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 59 User Cmd 9 Reset Sensors Default: Default: Selection: Selection: Blank, E, or P Blank, E, or P Function No. Function Name Alternate Keystroke Function No. Function Name Alternate Keystroke...
  • Page 60: Move To Area

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 60 Move to Area Default Text Default: Default: Selection: Blank, E, or P Selection: Blank, E, or P Function No. Function Name Alternate Keystroke Function No. Function Name Alternate Keystroke...
  • Page 61: 2.11.4 Authority Level Selections

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 61 Custom Functions Authority Level C Function 128 [through 143] Default: Default: Selection: 1 to 14 Selection: Blank, E, or P Enter the number of the authority level you want to program.
  • Page 62: L## Master Arm Delay

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 62 L## Perim Delay L## Master Arm Delay Default: Refer to the program record sheet Default: Refer to the program record sheet Selection: Blank or E Selection: Blank or E Function No.
  • Page 63: L## View Memory

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 63 • If enabled in Routing, Walk Start and Walk End L## View Memory Reports are sent to the central station receiver at the beginning and end of the test.
  • Page 64: L## Send Report

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 64 L## Send Report L## Cycle Door Default: Refer to the program record sheet Default: Refer to the program record sheet Selection: Blank or E Selection: Blank or E Function No.
  • Page 65: L## Secure Door-Door Mode Definitions

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 65 General Functions Table 27: L## Secure Door-Door Mode L## Chg Display Definitions Default: Refer to the program record sheet Door State Definition Selection: Blank or E Lock Door Normal Door: When a door is in the Function No.
  • Page 66: L## Del User

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 66 L## Del User L## User Cmd 7 Default: Refer to the program record sheet Default: Refer to the program record sheet Selection: Blank or E Selection: Blank or E Function No.
  • Page 67: L## Change Relay

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 67 L## Change Relay L## Service Walk Default: Refer to the program record sheet Default: Refer to the program record sheet Selection: Blank or E Selection: Blank or E Function No.
  • Page 68: L## Default Text

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 68 • Local event printing occurs without alarm L## Default Text annunciation or reports sent to the central station receiver. Default: Refer to the program record sheet • The D1255 Keypad shows a sequential count and...
  • Page 69: 2.11.5 Access Control Levels

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 69 L## Disarm Level L## Perimeter O/C Default: Refer to the program record sheet Default: Refer to the program record sheet Selection: I, D, or Blank Selection: Blank or E...
  • Page 70: Function List

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 70 2.12 Function List L## Function Level The Function List is accessed when the user presses Default: Refer to the program record sheet [MENU] (or the key corresponding to menu on the...
  • Page 71: Relay Parameters

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 71 • Relay Reports: When relay activity is reported to M## CC Address 1 [through 8] the receiver (refer to Section 2.3 Routing on page 13), on-board relays are reported as follows:...
  • Page 72: 2.13.1 Area Relays

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 72 Relay functions that must be reset manually with Change Relay function (COMMAND 54): A# Reset Sensors Fail To Close Force Armed Default: Duress Log % Full Selection: Blank, 1 to 128 (1 to 64 for D7412GV2), A, B, or C 2.13.1 Area Relays...
  • Page 73: A# Force Armed

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 73 A# Force Armed A# Area Fault Default: Blank Default: Blank Selection: Blank, 1 to 128 (1 to 64 for Selection: Blank, 1 to 128 (1 to 64 for D7412GV2), A, B, or C D7412GV2), A, B, or C This relay activates when this area is Force Armed.
  • Page 74: 2.13.2 Panel-Wide Relays

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 74 Programming Tips 2.13.2 Panel-Wide Relays 1. Burg Time needs a programmed bell period. This The following eleven relay options activate when they relay activates according to the bell pattern and occur anywhere in the control panel.
  • Page 75: Comm Fail

    D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 75 Summary Fire Tbl Comm Fail Default: Blank Default: Blank Selection: Blank, 1 to 128 (1 to 64 for Selection: Blank, 1 to 128 (1 to 64 for D7412GV2), A, B, or C...
  • Page 76 D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 76 Notes Bosch Security Systems | 5/05 | F001U003636B...
  • Page 77: 3.0 Radxusr1/Radxusr2

    User Groups U### Name Each user group can be assigned one For the D9412GV2, there are 249 groups (99 groups This name is logged and sent to the central station for for the D7412GV2) consisting of one user with a pass all the users in the group.
  • Page 78: Figure 4: User Group 122 Example

    D9412GV2/D7412GV2 | Program Entry Guide | 3.0 RADXUSR1/RADXUSR2 EN | 78 Figure 4: User Group 122 Example Master User: ID 122. ♦ CRD ID 122-0 ♦ Sub User -1: ID 122-1 CRD ID 122-1 ♦ Sub User -2: ID 122-2.
  • Page 79: U### Passcode

    D9412GV2/D7412GV2 | Program Entry Guide | 3.0 RADXUSR1/RADXUSR2 EN | 79 U### Passcode To enable this user’s pass code at all times, leave U### User Group blank. Default: Refer to the program record sheet Selection: Three to six digits ( 0 to 9)
  • Page 80: U### Mstr Site

    D9412GV2/D7412GV2 | Program Entry Guide | 3.0 RADXUSR1/RADXUSR2 EN | 80 For more information, refer to the Security Industry Association (SIA) Access Control 26-bit Wiegand U### Mstr Crd Data Reader Interface Standard. Default: Blank U### Mstr Site Selection: 00000 = (0) to 65534 or Blank (65535)
  • Page 81: 4.0 Radxpnts

    D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 81 The NEW RECORD program contains default entries 4.0 RADXPNTS and descriptions that match RPS defaults for point indexes. Refer to the D9412GV2/D7412GV2 Program Point Index Record Sheet (P/N: F01U003635) for defaults.
  • Page 82 D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 82 P ## Type Description Selection Interior: Interior points are armed only by master arming the area. They are not armed when using Perimeter Arming functions. These points are typically used to monitor interior detection devices such as interior doors, motion detectors, photoelectric beams, and carpet mats.
  • Page 83 D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 83 P ## Type Description Keyswitch Maintained: Program P## Pt Response as 1. Do not connect initiating devices to a Keyswitch point. Normal: The area is disarmed. Short: When this point changes from normal to open, the area arms.
  • Page 84 D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 84 P ## Type Description Selection D279 (O/C Non-Priority): The D279 provides point arming and disarming independent of the area arm state. A non-priority D279 point arm state does not affect the area arm state.
  • Page 85: Point Responses

    D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 85 Alarm Verification: A Fire point can delay an alarm Point Responses by the length of time programmed in A# Verify Time 4.2.1 Applications for Point Responses 9, in the Area Parameters. Combined with...
  • Page 86: P## Pt Response

    D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 86 P## Pt Response Default: Refer to the program record sheet Selection: 0 to F Controlled (Non-24-Hour Points) Point Response Armed Open Armed Short Disarmed Open Disarmed Short 24-Hour Points...
  • Page 87: P## Entry Delay

    D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 87 Entry Tone can also be turned off when P## Entry Delay programming your CC Entry Tone, in Section 2.10 Keypad (Command Center) Default: Refer to the program record sheet...
  • Page 88: P## Audible After 2 Failures

    D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 88 P## Invisible Pt If the point restores and the fire alarm is not silenced from the keypad, the fire alarm Default: Refer to the program record sheet output continues until Fire Bell time expires.
  • Page 89: P## Buzz On Fault

    D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 89 P## Buzz On Fault Default: Blank Selection: Blank, 1 to 3 Selection Operation for Controlled Points Operation for 24-hour Points (Point Types 1, 2, and 3) (Point Type 0)
  • Page 90: P## Rlyresp Type

    This requires connecting D8129 OctoRelays Send event reports occurring from this to Zonex Bus 1 and Zonex Bus 2 (D9412GV2 only). point while the area is disarmed. Refer to the address settings on the back of the...
  • Page 91: P## Local While Armed

    D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 91 P## Local While Armed P## FA Retrnable Default: Default: Selection: Yes or No Selection: Yes or No Suppress Alarm, Trouble and This point automatically returns to the Restoral* Reports from this point system when it restores to normal.
  • Page 92: Bypassing A Point

    D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 92 P## Bypassable Programming Bypassable as Yes for Default: Cross points can cause missed Cross- Selection: Yes or No Point alarms. For example, if Points 1 and 2 were programmed as Cross points and...
  • Page 93: P## Defer Bp Report

    P## Type Use this option to prevent (0 to F) points D9412GV2 and D7412GV2 to support the Cross Point that are bypassed by the user (COMMAND BYPASS) function. There are 31 Cross Point Groups in the from occurring until the area is armed. When the area D9412GV2 and ten in the D7412GV2.
  • Page 94: Point Assignments

    These entries assign point indexes to Points 1 to 127, Default: Refer to the program record sheet 129 to 247 for the D9412GV2 and Points 1 to 75 for the D7412GV2, and assign the points to the areas. Selection: Yes or No Also included in this section are parameters used to set Enable alarm verification on this point.
  • Page 95: P### Area Assign

    D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 95 P### Point Index P### Debounce Default: Refer to the program record sheet Default: Selection: Blank (00) to 31 Selection: 1 to 15 P## Index This entry selects one of the 31 codes that .300 seconds...
  • Page 96: P### Bfsk/Relay Codes/Relays

    Point 243 Area 4 as 0. Point 244 Area 5 On the D9412GV2, do not use Relays 73 Point 245 Area 6 through 80 for Area or Panel-Wide Relay Point 246 Area 7 function when this prompt is enabled for the...
  • Page 97: Command 7 And Command 9

    The value in this entry selects one of the digits shown for reporting in BFSK or for activating relays 73 to 80 CMD7 BFSK/Relay (on the D9412GV2) or relays 9 to 16 (for the Default: D7412GV2) when a COMMAND 9 is initiated (refer...
  • Page 98 D9412GV2/D7412GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 98 Notes Bosch Security Systems | 5/05 | F001U003636B...
  • Page 99: 5.0 Radxsked

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 99 Table 32: Window Selections 5.0 RADXSKED Windows Selection Sked # Window Sked # Window Use this programming module to define the windows Open Close for Opening and Closing and User Access.
  • Page 100: W# Monday

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 100 • If Disable O/C in Window is set to No and the W# Monday area is disarmed at any time, an Opening Event is sent without an Early to Open or Late to Open Default: modifier.
  • Page 101: Figure 5: Example Opening Window Timeline Table 29: (Using Two Opening Windows On Same Table 30: Day)

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 101 W# Open Window Start Make time entries using a 24-hour clock. For example: Default: 00: 00 Midnight is entered as 00:00 Selection: HH:MM (hours and minutes) 7:00 AM is entered as 07:00...
  • Page 102: Programming For Two Same Day Opening Windows

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 102 Table 33: Programming for Two Same Day Opening Windows (refer to Figure 5) Open Close Early Early eXcept On Holiday Day of Week Begin Start Stop Begin Start Stop...
  • Page 103: W# Close Window Stop Programming Example

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 103 00:00 is midnight, 23:59 is 11:59 PM. Make entries This program item is one of three required to create a using a 24-hour clock (for example, 7:00 AM is Closing Window.
  • Page 104: W# Xept Holiday

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 104 W# Xept Holiday W# Holiday 1 Default: Default: Selection: Yes or No Selection: Yes or No Do not activate this window on Use Holiday Index 1 with this holidays.
  • Page 105: Opening And Closing Windows Worksheet

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 105 Table 36: Opening and Closing Windows Worksheet Open Close eXcept Early Early Holiday Day of Week Begin Start Stop Begin Start Stop Holiday Index Area(s) S M T W T F S...
  • Page 106: User Group Windows

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 106 Table 39: Delivery Schedule* Open Close eXcept Early Early Holiday Day of Week Begin Start Stop Begin Start Stop Holiday Index Area(s) S M T W T F S...
  • Page 107: Uw# Sunday

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 107 UW# Sunday UW# Group Enable Default: Default: 00:00 Selection: Yes or No Selection: HH:MM (hours and minutes) This prompt, and the next six day of the week prompts, select the days of the week that the User This prompt must be programmed if this Group Window is active.
  • Page 108: Holiday Indexes For User Group Windows

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 108 Each sked can be programmed with up to four 5.1.3 Holiday Indexes for User Group Windows Holiday Indexes. The Holiday Indexes can execute You can enable up to four Holiday Indexes to use with the sked on the holidays as well as on the date or User Group Windows.
  • Page 109: S## Function Code

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 109 S## Function Code Enter the function code you want this sked to execute. Sked Function 12 is reserved and is not a valid entry. The D5200 Programmer automatically retrieves the appropriate sub-menu when the user enters a function code.
  • Page 110: S## Area 1[Through 8]

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 110 Default: Blank Selection: 1 to 11, 13 to 24, 28, 29 Unbypass All Points: This function Unbypass all S## Area 1[through 8] is not available as a keypad function.
  • Page 111: S## Defer Test

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 111 Default: Blank Selection: 1 to 11, 13 to 24, 28, 29 Test Report: This function emulates Defer the Test S## Defer Test the Send Report? keypad function. Report. This function generates a Test Report...
  • Page 112: S## Cmd Center

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 112 Default: Blank Selection: 1 to 11, 13 to 24, 28, 29 Execute Custom Func: This Blank (0) No keypad is S## Cmd Center specified for function emulates any of the custom...
  • Page 113: S## Cmd Center 1[Through 8]

    The D9412GV2 supports eight doors; the D7412GV2 supports two doors. To regulate a user’s access for certain doors, assign the user a different authority level # with the same authority functions enabled. For example, a user can be assigned Authority Level 1 for Door 1 and Authority Level 2 for the remaining doors.
  • Page 114: S## Door 1 [Through 8]

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 114 Default: Blank Selection: 1 to 11, 13 to 24, 28, 29 Unlock Door: This function Unlock Door #. S## Door 1 [through 8] emulates the UNLOCK? Default: No 12345678 keypad function for unlocking a door.
  • Page 115: S## Door 1 [Through 8]

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 115 Default: Blank Selection: 1 to 11, 13 to 24, 28, 29 No Entry Events On: The Enable the sending S## Door 1 [through 8] control panel can log No Entry...
  • Page 116: S## Time

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 116 S## Time S## Sunday Default: 00:00 Default: Selection: HH:MM (hours and minutes) Selection: Yes or No Enter the time that the sked executes. Make entries Activate this sked on Sundays.
  • Page 117: Holiday Indexes

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 117 Holiday Indexes S## Xept Holiday This programming module has two sections: Default: Add/Change/Delete and View Holidays. Use the Selection: Yes or No Add/Change/Delete section to program the Holiday Indexes. The View Holidays section is a view-only Prevent this sked from operating on section provided for your convenience.
  • Page 118: View Holidays

    D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 118 Holiday Index 1 5.3.2 View Holidays The View Holidays section is a view only section Default: provided for your convenience. Use View Holidays to Selection: Yes or No review the dates you programmed into each of the Holiday Indexes.
  • Page 119: 6.0 Gv2Aux

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 119 SDI Automation 6.0 GV2AUX SDI automation defines the characteristics of a serial interface module (SIM) when used with home or Introduction business automation software. The SIM is a two-way...
  • Page 120: Parity/Stop

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 120 Parity/Stop DTR Control Default: No/1 Default: Selection: No/1, No/2, Odd/1, Even/1 Selection: On, AutoD, Off No/1 No parity, 1 stop bit Sets DTR to on (hardware control). No/2 No parity, 2 stop bits AutoD Sets this to Auto DTR.
  • Page 121: Sdi Rps Parameters

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 121 Enable SDI RPS determines if the control panel SDI RPS Parameters allows RPS communications over the SDI bus. This Configure remote programming software (RPS) item must be set to Yes if you plan to use the external...
  • Page 122: Command 43 Flow Chart

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 122 Figure 6: COMMAND 43 Flow Chart 1 - COMMAND 43 7 - Begins RPS session over the network 2 - Contact RPS? 8 - Seizes phone line and begins RPS session...
  • Page 123: Using An External Modem

    The seven prompts on page 126 help to configure the Type [A][T][&][N][6][Enter] requirements necessary to connect an external modem For other modems, consult the instructions to a D9412GV2 or D7412GV2 Control Panel using a provided with the device for the correct text D9133DC. This configuration allows communication string.
  • Page 124: Figure 8: Com Port Selection Within

    SWITCHED AUX service is to be provided with this equipment. Terminal D9412GV2 Control/Communicator is UL Listed For Central Station, Local, Remote Station and RELAY C ZONEX IN 2 Household Fire Alarm, and Central Station, Local, Police Station Connect, Household Burglar Alarm and Encrypted Line Security when communicating via a network.
  • Page 125 D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 125 To use an off-the-shelf external modem and a D9133DC serial module to connect to the control panel using RPS, use the following settings: 1. GV2AUX\ENHANCED COMM\Enhanced Comm\No 2. GV2AUX\SDI RPS PARAMETERS\Enable SDI RPS\Yes 3.
  • Page 126: Enable Ext Modem

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 126 Enable Ext Modem RPS Line Monitor Default: Default: Selection: Yes or No Selection: Yes or No Enable SDI Address 88 for use with Not used. Keep this item set to No.
  • Page 127: Programming Path Numbers And Ip Addresses For Enhanced Communications

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 127 Path # IP Add1 Programming Path Numbers and IP Addresses for Enhanced Default: Communications Selection: 0 to 255 Enhanced communications is the ability to 0 to 255 Enter the first three digits of the IP communicate by some means other than the standard address.
  • Page 128: Figure 11: Poll Rate Timeline

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 128 The control panel readjusts the poll rate if it Path # Poll Rate is less than 300 seconds to a temporary poll rate of 300 seconds when online with Default: RPS.
  • Page 129: Path # Ack Wait

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 129 Example of Retry Count: Determines how long the control panel waits for an acknowledgment from the central station after a An acknowledgment of the heartbeat was not received Heartbeat Event (poll) or an actual event was within 10 seconds.
  • Page 130: Sdi Rps/Enhanced Communications Configuration

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 130 SDI RPS/Enhanced RTS Controll Communications Configuration Default: This section provides the necessary prompts for Selection: On, AutoX, Off, AutoR configuring the SDI-Network Interface Module (NIM) when using it for SDI RPS or SDI enhanced Sets RTS to on (hardware control).
  • Page 131: Route Group Attempts

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 131 Miscellaneous 9133 Supervision Fire Supv Res Type Default: Selection: Yes or No Default: Supervise the network interface Selection: 0, 1, 2 module (NIM). The control panel sends a FIRE...
  • Page 132: Cross Point Parameters

    Events are not generated at the Cross Point Groups were established in the time the re-sound occurs. D9412GV2 and D7412GV2 to support the Cross Point functions. There are 31 Cross Point Groups in the Early Ambush Timer D9412GV2 and ten in the D7412GV2.
  • Page 133: Cross Point Ranges Within Groups

    D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 133 Conversely, if a single Cross Point detects an alarm, then restores, and no other conditions occur, an Table 41: Cross Point Ranges Within Groups Unverified Event is generated for that point. A second...
  • Page 134 D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 134 Notes Bosch Security Systems | 5/05 | F001U003636B...
  • Page 135: Radxaxs

    D9412GV2/D7412GV2 | Program Entry Guide | 7.0 RADXAXS EN | 135 D#CC#Scope RADXAXS Default: Blank Door Profile Selection: Blank, 1 to 8 This programming category is used to: 1 to 8 Determines disarming rights. The • Assign an area that also activates the D9210B user’s access level and the...
  • Page 136: Effects Of Programming On Custom Function Activation

    D9412GV2/D7412GV2 | Program Entry Guide | 7.0 RADXAXS EN | 136 When assigning Points 1 to 8 (control Table 42: Effects of Programming on Custom panel zones), the end-of-line (EOL) Function Activation resistors must be removed from the control panel.
  • Page 137: D# Auto Door

    D9412GV2/D7412GV2 | Program Entry Guide | 7.0 RADXAXS EN | 137 D# Auto Door? This unlocks the door regardless of the armed state. Default: Selection: Yes or No D# Entry When the area assigned in Each fire alarm that is generated causes a...
  • Page 138: Strike Profile

    D9412GV2/D7412GV2 | Program Entry Guide | 7.0 RADXAXS EN | 138 Strike Profile D# Buzz Time This programming category is used to create a specific Default: 2 seconds door profile for: Selection: Blank, 1 second to 240 seconds • Strike and shunt times.
  • Page 139: Event Profile

    D9412GV2/D7412GV2 | Program Entry Guide | 7.0 RADXAXS EN | 139 D# Deact On Open? D# REXShunt Only? Default: Default: Selection: Yes or No Selection: Yes or No Strike deactivates when the door is Programmed shunt time activates so opened after a valid Access Granted the door can be manually opened.
  • Page 140: D# Access Granted

    D9412GV2/D7412GV2 | Program Entry Guide | 7.0 RADXAXS EN | 140 D# Enter Request? D# Access Granted? Default: Default: Selection: Yes or No Selection: Yes or No A Door RTE Event from this door Access Events from this door controller is sent to the control panel controller are sent to the control for processing.
  • Page 141: Programming Prompts Directory

    D9412GV2/D7412GV2 | Program Entry Guide | Programming Prompts Directory EN | 141 Programming Prompts Directory GV2MAIN ............... 9 AC Fail Time ........... 25 Phone..............9 AC Fail/Res Rpt........26 Phone 1 ............9 AC Tag Along ......... 26 Phone 2 ............9 AC/Battery Buzz ........
  • Page 142 D9412GV2/D7412GV2 | Program Entry Guide | Programming Prompts Directory EN | 142 A# FA Bypass Max.........33 CC# Entry Tone ........48 A# Delay Res...........33 CC# Exit Tone........49 A# Exit Tone ...........34 CC# Arm Now Warn......49 A# Exit Dly Time ........34 CC# Close Door ........
  • Page 143 D9412GV2/D7412GV2 | Program Entry Guide | Programming Prompts Directory EN | 143 Print Log ...........58 L## View Log ......... 66 User Cmd 7..........58 L## Print Log.......... 66 User Cmd 9..........59 L## User Cmd 7........66 Bypass a Pt ..........59 L## User Cmd 9........66 Unbypass a Pt ..........59...
  • Page 144 D9412GV2/D7412GV2 | Program Entry Guide | Programming Prompts Directory EN | 144 A# Area Fault ..........73 P## Watch Point........89 A# Duress Relay ........73 P## RlyResp Type ......... 90 A# Perim Fault ........73 P## Disp as Dvc ........90 A# Silent Alarm ........73 P## Local While Disarmed ....
  • Page 145 D9412GV2/D7412GV2 | Program Entry Guide | Programming Prompts Directory EN | 145 W# Open Early Begin ......100 S## Custom Func......112 W# Open Window Start ......101 S## Cmd Center 1[through 8] ..113 W# Open Window Stop ......101 S## Access Ctl Level # ....113 W# Close Early Begin ......102...
  • Page 146 D9412GV2/D7412GV2 | Program Entry Guide | Programming Prompts Directory EN | 146 9133 Supervision ........120 Enable Protocol Type ......131 RTS Control...........120 Enable Anti Replay....... 131 DTR Control..........120 Fire Trouble Resound......132 Status Rate..........120 Early Ambush Timer ......132 SDI RPS Parameters ........121 Secondary Ambush Code.....
  • Page 147 D9412GV2/D7412GV2 | Program Entry Guide | Programming Prompts Directory EN | 147 Notes Bosch Security Systems | 5/05 | F001U003636B...
  • Page 148 Bosch Security Systems 130 Perinton Parkway Fairport, NY 14450-9199 Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 © 2005 Bosch Security Systems F001U003636B...