Programming Path Numbers And Ip Addresses For Enhanced Communications - Bosch D7212GV3 Program Entry Manual

Table of Contents

Advertisement

D7212GV3 | Program Entry Guide | 6.0
6.6
Programming Path Numbers and IP
Addresses for Enhanced
Communications
Enhanced communications is the ability to
communicate by some means other than the
standard digital dialer. In this section, programmable
parameters allow you to define up to four separate
enhanced communication paths to which events can
be routed. To route an event (such as an Alarm or
Trouble) to an enhanced communication path,
additional programming must also be completed in
Section 2.3 Routing on page 12 and Section on
page 21.
Enhanced Comm
Default:
No
Selection:
Yes or No
Yes
Enable enhanced communications
over the SDI bus.
No
Do not enable enhanced
communications over the SDI bus.
Determines if the control panel allows enhanced
communications over the SDI bus.
Events can be routed to as many as four available
enhanced communication paths through the SDI bus.
If an event (or group of events) is routed to an SDI
path, the number entered in Primary Device
determines which SDI path is used (provided that
RG# Prim, Primary SDI was set to Yes in Routing).
If events are to be routed to an IP address (in a
private LAN or WAN application), determine which
path is used (Path 1 to Path 4), and enter the
appropriate IP Address for that path (refer to Path #
IP Address on page 117).
If events are to be routed to an SDI Path but not to an
IP Address, allow the setting for Path # IP Address
to remain at 0. Path # Poll Rate, Path # Ack Wait,
and Path # Retry Count must be programmed.
Keypad Programming to Enable or Disable
Enhanced Comm
D1255
1. Refer to Figure 1 on page 6 to access Keypad
Programming and navigate to the ENHANCED
COMM option. Press [ENT].
2. The keypad shows the current setting by
alternating between COMMUNICATIONS> and
ENHANCED> YES or NO. To configure
enhanced communications, press [ENT].
3. Press [NEXT] or [PREV] to toggle to YES to
enable enhanced communication or No to
disable enhanced communication, and then
press [ENT].
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
AUXPARM
When the keypad reads PARAMETER SAVED, your
selection has been configured.
D1260
1. Refer to Figure 2 on page 7 to access Keypad
Programming and navigate to the Enhanced
Comm option. Press the Enhanced Comm
softkey.
2. The current Enhanced Enabled configuration
shows (for example, Enhanced Enabled: Yes).
3. Press the Edit softkey to change the
configuration.
4. Press the Yes or No softkey, and then press the
Save softkey to save the changes.
When the keypad reads Parameter Saved, your
selection is configured.
Path # IP Address
Default:
Selection:
0 to
There are four numbers in a valid IP
255
address. Leading zeros are not required.
Path # IP Address contains the IP addresses for
each of the four enhanced communication paths
available.
An IP address has four fields. Each field has a range
of 0 to 255. For example, an IP address is expressed
as 110.227.64.190. See your network administrator
to obtain the appropriate IP address for contacting a
central station receiver.
Refer to Keypad Programming of Path # IP
Adddress, Path # Port Number, and Path # Poll Rate
on page 118.
Path # Port Number
Default:
Selection:
This prompt specifies the destination port number for
each of the four enhanced communication route path
destinations.
Whenever an IP address or port number
configured in the control panel is
changed, the central station must
resynchronize the control panel's
anti-replay/anti-substitution static key.
Refer to Keypad Programming of Path # IP
Adddress, Path # Port Number, and Path # Poll Rate
on page 118.
0.0.0.0
0.0.0.0 to 255.255.255.255
7700
1 to 65535
EN | 117