Figure 5: Example Opening Window Timeline; Table 26: Programming For Two Same Day Opening Windows (Refer To Figure 5); Table 27: Programming To Link Two Days Over Midnight - Bosch D7212GV3 Program Entry Manual

Table of Contents

Advertisement

D7212GV3 | Program Entry Guide | 5.0
Figure 5: Example Opening Window Timeline (using two Opening Windows on same day)
1
1 - Areas disarmed between midnight and 6 AM
generate Opening Reports.
2 - Areas disarmed between 6 AM and 7 AM
generate Early to Open Reports.
3 - If the area is disarmed between 7 AM and 8 AM
regular Opening Reports are generated. If
Disable O/C in Window is programmed Yes the
Opening Report is not sent to the central station.
4 - If the area is not disarmed by 8:01 AM, a Fail to
Open Event is generated if Fail to Open is
programmed Yes in Opening and Closing
Options.
5 - If the user disarms the area between 8:01 AM
and 12:59, PM a Late to Open Event is
generated.

Table 26: Programming for Two Same Day Opening Windows (refer to Figure 5)

W#
Day of Week
1
S M T W T F S
2
S M T W T F S
Do not program a single window to cross the midnight boundary. The window stop time must be later than the
window start time. To program a window that effectively crosses the midnight boundary, you must program two
windows.
For example, to program windows for an area that opens between 11:30 PM and 12:30 AM, five days a week,
use two windows as shown in Table 27.

Table 27: Programming to Link Two Days over Midnight

W#
Day of Week
1
S M T W T F S
2
S M T W T F S
The setting for midnight is 00:00.
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Schedules (Skeds)
3
2
Open
Early
Begin
Start
Stop
06: 00
07 : 00
08: 00
13 : 00
14 : 00
15 : 00
Open
Early
Begin
Start
Stop
22: 00
23 : 30
23: 59
00 : 00
00 : 00
00 : 30
4
6
5
6 - Areas that are disarmed between 1 PM and 2
PM generate Early to Open Reports.
7 - If the area is disarmed between 2 PM and 3
PM regular Opening Reports are generated. If
Disable O/C in Window is programmed Yes,
the Opening Report is not transmitted to the
central station.
8 - If the area is not disarmed by 3:01 PM, a Fail to
Open Event is generated if Fail to Open is
programmed Yes in Opening and Closing
Options.
9 - If the user disarms the area between 3:01 PM
and 11:59 PM, a Late to Open Event is
generated.
Close
Early
eXcept On
Begin
Start
Stop
Yes / No
Yes / No
*
Close
Early
eXcept On
Begin
Start
Stop
Yes / No
Yes / No
8
9
7
Holiday
Holiday
Index
1 2 3 4
1 2 3 4 5 6 7 8
1 2 3 4
1 2 3 4 5 6 7 8
Holiday
Holiday
Index
1 2 3 4
1 2 3 4 5 6 7 8
1 2 3 4
1 2 3 4 5 6 7 8
EN | 97