Use an entry of two or higher. Interior
Follower points need a Debounce value
of at least three.
P### Relay
Default:
Refer to the program record sheet
Selection:
0 to 8
Use this option to activate a relay when the point is
faulted. Refer to Table 24.
Relays do not activate for Fire
Supervisory or Non-Fire Supervisory
points.

Table 24: P### Relay Codes/Relays

D8129 on Zonex Bus 1 for D7212GV3*
Relay Code
1
2
3
4
5
6
7
8
Do not assign a relay to Invisible points.
To avoid activating one of the associated
relays, program this prompt as 0.
Two relays can activate when this point
enters into alarm if the P## Rly Resp
Type for this point is programmed.
Use these codes to activate relays on the
D8129 OctoRelay (or C8137 Transmitter
Interface). You can assign the same code
to several points providing a summary
zone alarm output. When the point enters
into alarm, the relay activates. When the
alarm is acknowledged and is no longer
scrolling in the keypad display, the relay
resets.
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Points
Faults Relay
9
10
11
12
13
14
15
16
P### Point Text
Default:
Refer to the program record sheet
Selection:
Up to sixteen alphanumeric
characters
Enter alphabetic characters (A to Z) in capital letters.
Enter up to sixteen characters of text to describe the
point. This point text is shown at keypads, if the point
is programmed as visible, and sent to the central
station receiver when transmitting in Modem IIIa
format (if it is a reporting point).
Include the point number in custom point text. This
helps the user when viewing events, creating
bypasses, and so on. It can also simplify
troubleshooting.
4.4

COMMAND 7 and COMMAND 9

These entries assign point indexes, BFSK report
code, BFSK relay that activates, and the text for the
COMMAND 7 and COMMAND 9 keypad functions.
CMD7 Point Index
Default:
31
Selection:
0 to 31
This entry selects one of the 31 P## Index codes that
define how the control panel reacts when a
COMMAND 7 is initiated (refer to the P### Relay
prompt on page 93).
The point index code used for
COMMAND 7 must not be used for any
other points on the system.
CMD7 Relay
Default:
1
Selection:
0 to 9
This entry selects a relay (9 to 16 for the D7212GV3)
when COMMAND 7 is initiated (refer to the P###
Relay prompt on page 93 for relay number
association).
COMMAND 7 does not activate the
Summary Fire Alarm relay.
CMD7 Point Text
Default:
COMMAND 7
Selection:
Up to sixteen alphanumeric
characters
Enter alphabetic characters A to Z in capital letters
EN | 93