3.1

Passcode or Token Worksheet

These programming items assign:
a passcode to user groups 001 through 099,
areas by authority level, and
a User Group Window.
3.1.1

User Groups

For the D7212GV3, there are 99 groups consisting of
one user with a passcode and token (master) and
three users with tokens or cards but not a passcode
(sub-user). All users in the group share the same
authority level as the master user.
3.1.2

Passcodes

In a control panel with factory default settings, only
the master user has an assigned passcode. A
passcode can be three to six digits. Entering three
digits in User ### chooses the user. Programming
the U001 Passcode assigns a passcode to the
master user. Sub-users cannot use the passcode. Do
not assign tokens or cards to User ID 0 (zero), which
is reserved for the service passcode.
Passcode Tamper
If a user enters six consecutive invalid passcodes at
the same keypad, the control panel sends a User
Code Tamper report to the central station. The invalid
passcode count resets when a valid passcode is
entered at the same keypad. Refer to R# Usr Code
Tamper in Table 7 on page 17 for information on
enabling this report.
The passcode tamper condition is also reported in a
manually initiated Extended Test Report and to RPS
through control panel diagnostics. As a result, the
tamper condition is reset after the successful
completion of a manual report or when disconnecting
from an RPS session. The tamper condition is not
reset when the control panel reboots.
3.1.3

User Group Window

Use U### User Group to enable and disable the
U### Passcode for up to eight different time periods
throughout the day. Assign the number (1 to 8)
programmed in U### User Group to a User
Windows #. If the user is outside a window,
COMMAND DISABLED appears on the keypad after
the user enters the passcode and presses [ENTER].
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Passcodes, Access Credentials, and User Groups
3.1.4

User Name

Each user group can be assigned one U### Name.
This name is logged and sent to the central station
for all the users in the group. The user ID is used to
differentiate which user's token or card was
executed.
When using a D1260 Keypad, User 099
text is used for contact information text
(such as telephone numbers). If a D1260
is installed on the system, do not use
User 099 for user ID information.
3.1.5

Reporting and Logging

Phone # Format must be ModemIIIa
following reports sent to the central station.
Regardless of the reporting format, they log and print
at the local printer as shown in Figure 4 on page 75.
Each sub-user is identified by the master user's
three-digit number plus an extension of 0, 1, 2, or 3.
These numbers are called Sub-user ID Codes.
Figure 4 on page 75 shows all the users for User
Group 122 as they would appear.