30.
5. Remove memory card identified and check for connector pin damage on memory card and CPU memory
card slot.
31.
a) Replace affected commodity if damage is found.
32.
6. Swap the memory card in the slot identified, with a memory card from another slot with the same
configuration of DIMMs (size, type, number)
33.
7. Restart the server and see if problem still identifies the same memory card slot.
a) If problem remains with original slot, replace the I/O board assembly.
34.
b) If problem occurs in slot where original memory card was moved to, replace the memory card.
35.
80070608-1408ffff Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: A system power fault has occurred.
May also be shown as 800706081408ffff or 0x800706081408ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response:
1.
Critical: Do Not attempt to power the system on, or AC cycle. Do so only when instructed to in the following
steps.
2.
1. Using the IMM web interface, determine the version of FPGA installed and capture an IMM log for support
reference.
3.
Perform the following actions for the FPGA version installed.
4.
[FPGA versions lower than 4.00]
5.
2. Remove AC power.
3. Remove memory card identified and check for connector pin damage on memory card and CPU memory
6.
card slot.
a) Replace affected commodity if damage is found.
7.
4. Swap the memory card in the slot identified, with a memory card from another slot with the same
8.
configuration of DIMMs (size, type, number)
5. Restart the server and see if problem still identifies the same memory card slot.
9.
10.
a) If problem remains with original slot, replace the I/O board assembly.
11.
b) If problem occurs in slot where original memory card was moved to, replace the memory card.
12.
[FPGA versions 4.00 and 4.01]
13.
2. If local, pull out the Operator Information Panel, observe and make note of what is being displayed on the
Checkpoint display for support reference.
14.
3. Using the IMM web interface, capture a 'Service Data' file if available (note:) for support reference.
15.
4. Remove AC power.
16.
5. Remove memory card identified and check for connector pin damage on memory card and CPU memory
card slot.
17.
a) Replace affected commodity if damage is found.
18.
6. Swap the memory card in the slot identified, with a memory card from another slot with the same
configuration of DIMMs (size, type, number)
19.
7. Restart the server and see if problem still identifies the same memory card slot.
a) If problem remains with original slot, replace the I/O board assembly.
20.
b) If problem occurs in slot where original memory card was moved to, replace the memory card.
21.
[FPGA version 5.01]
22.
Appendix B. Integrated management module error messages
80070608-1408ffff
421