800b0108-1381ffff • 800b010a-1e81ffff
800b0108-1381ffff Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Power Supply Redundancy has been lost.
May also be shown as 800b01081381ffff or 0x800b01081381ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 9
Automatically notify Support: No
User response:
1. Power Unit :Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
800b0108-1382ffff Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: MEU Power Supply Redundancy has been lost.
May also be shown as 800b01081382ffff or 0x800b01081382ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 9
Automatically notify Support: No
User response:
1. Power Unit :Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
800b010a-1e81ffff Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Fan Redundancy has been lost.
May also be shown as 800b010a1e81ffff or 0x800b010a1e81ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 1