816f0021-2582ffff • 816f0107-0301ffff
816f0021-2582ffff Fault condition removed on slot [PhysicalConnectorElementName] on system
[ComputerSystemElementName].
Explanation: IMM has detected that a fault condition in a PCIe slot has been removed.
May also be shown as 816f00212582ffff or 0x816f00212582ffff
Severity: Info
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0331
SNMP Trap ID: 50
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
816f0028-2584ffff Sensor [SensorElementName] has returned to normal on management system
[ComputerSystemElementName].
Explanation: IMM was unable to communicate properly on an internet interface has deasserted
May also be shown as 816f00282584ffff or 0x816f00282584ffff
Severity: Info
Alert Category: Warning
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0399
SNMP Trap ID: 60
Automatically notify Support: No
User response: no action; information only.
816f0107-0301ffff An Over-Temperature Condition has been removed on [ProcessorElementName].
Explanation: The microprocessor 1 temperature has returned to below the critical level.
May also be shown as 816f01070301ffff or 0x816f01070301ffff
Severity: Info
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0037
SNMP Trap ID: 0
Automatically notify Support: No
User response: No action; information only.