806f010d-040affff • 806f010d-040bffff
806f010d-040affff The Drive [StorageVolumeElementName] has been disabled due to a detected fault.
Explanation: The drive 10 has been disabled (defunct) due to a fault detected by the controller.
May also be shown as 806f010d040affff or 0x806f010d040affff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.
806f010d-040bffff The Drive [StorageVolumeElementName] has been disabled due to a detected fault.
Explanation: The drive 11 has been disabled (defunct) due to a fault detected by the controller.
May also be shown as 806f010d040bffff or 0x806f010d040bffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.
512
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide