IBM X3950 X5 Problem Determination And Service Manual page 742

Types 7145, 7146, 7143, and 7191
Hide thumbs Also See for X3950 X5:
Table of Contents

Advertisement

806f070c-2589ffff • 806f070c-258bffff
806f070c-2589ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Explanation: A memory configuration (memory card 4 bank) error has occurred.
May also be shown as 806f070c2589ffff or 0x806f070c2589ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure the memory cards are installed in the correct sequence.
806f070c-258affff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Explanation: A memory configuration (memory card 5 bank) error has occurred.
May also be shown as 806f070c258affff or 0x806f070c258affff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure the memory cards are installed in the correct sequence.
806f070c-258bffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Explanation: A memory configuration (memory card 6 bank) error has occurred.
May also be shown as 806f070c258bffff or 0x806f070c258bffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure the memory cards are installed in the correct sequence.
726
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3850 x5

Table of Contents