806f040c-18810013 [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName].
Explanation: DIMM 19 in memory expansion module(MEU) has been Disabled.
May also be shown as 806f040c18810013 or 0x806f040c18810013
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault, follow the suggested actions for that error event and restart
the server.
3. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM
through the Setup utility or the Advanced Settings Utility (ASU).
806f040c-18810014 [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName].
Explanation: DIMM 20 in memory expansion module(MEU) has been Disabled.
May also be shown as 806f040c18810014 or 0x806f040c18810014
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault, follow the suggested actions for that error event and restart
the server.
3. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM
through the Setup utility or the Advanced Settings Utility (ASU).
806f040c-18810013 • 806f040c-18810014
Appendix B. Integrated management module error messages