IBM X3950 X5 Problem Determination And Service Manual page 473

Types 7145, 7146, 7143, and 7191
Hide thumbs Also See for X3950 X5:
Table of Contents

Advertisement

806f0108-0a01ffff • 806f0108-1881ffff
806f0108-0a01ffff [PowerSupplyElementName] has Failed.
Explanation: IMM has detected a Fault on Power Supply 1.
May also be shown as 806f01080a01ffff or 0x806f01080a01ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: Yes
User response: Check the log for additional Power Supply Failure. Replace the Power Supply 1, if needed
806f0108-0a02ffff [PowerSupplyElementName] has Failed.
Explanation: IMM has detected a Fault on Power Supply 2.
May also be shown as 806f01080a02ffff or 0x806f01080a02ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: Yes
User response: Check the log for additional Power Supply Failure. Replace the Power Supply 2, if needed
806f0108-1881ffff [PowerSupplyElementName] has Failed.
Explanation: Memory expansion module power supply 2 error detected.
May also be shown as 806f01081881ffff or 0x806f01081881ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: No
User response:
1. Check memory expansion module LEDs.
2. Check memory expansion module power supply 2 LEDs.
3. Replace the memory expansion module power supply 2.