IBM X3950 X5 Problem Determination And Service Manual page 707

Types 7145, 7146, 7143, and 7191
Hide thumbs Also See for X3950 X5:
Table of Contents

Advertisement

806f060d-040effff • 806f060d-040fffff
806f060d-040effff Array in system [ComputerSystemElementName] has failed.
Explanation: The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array
all member drives will report this message.
May also be shown as 806f060d040effff or 0x806f060d040effff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v Replace the hard disk drives that are indicated by a lit status LED.
v Recreate the array.
v Restore data from backup.
806f060d-040fffff Array in system [ComputerSystemElementName] has failed.
Explanation: The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array
all member drives will report this message.
May also be shown as 806f060d040fffff or 0x806f060d040fffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v Replace the hard disk drives that are indicated by a lit status LED.
v Recreate the array.
v Restore data from backup.
691
Appendix B. Integrated management module error messages

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3850 x5

Table of Contents