IBM X3950 X5 Problem Determination And Service Manual page 411

Types 7145, 7146, 7143, and 7191
Hide thumbs Also See for X3950 X5:
Table of Contents

Advertisement

80010204-1d07ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: IMM has detected the speed of MEU Fan 2 has gone low.
May also be shown as 800102041d07ffff or 0x800102041d07ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
Reseat the failing fan indicated by the lit LED on the fan.
v
Replace Fan.
v
80010204-1d08ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: IMM has detected the speed of MEU Fan 3 has gone low.
May also be shown as 800102041d08ffff or 0x800102041d08ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
Reseat the failing fan indicated by the lit LED on the fan.
v
Replace Fan.
v
80010204-1d09ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: IMM has detected the speed of MEU Fan 4 has gone low.
May also be shown as 800102041d09ffff or 0x800102041d09ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
Reseat the failing fan indicated by the lit LED on the fan.
v
v
Replace Fan.
80010204-1d07ffff • 80010204-1d09ffff
Appendix B. Integrated management module error messages
395

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3850 x5

Table of Contents