800b030c-2581ffff • 800b050a-1e82ffff
800b030c-2581ffff Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for
[RedundancySetElementName] has asserted.
Explanation: Backup Memory has transitioned from Redundancy Degraded or Fully Redundant to
Non-redundant:Sufficient.
May also be shown as 800b030c2581ffff or 0x800b030c2581ffff
Severity: Warning
Alert Category: Warning
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0806
SNMP Trap ID: 43
Automatically notify Support: No
User response:
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
2. Re-enable mirroring in the Setup utility.
800b050a-1e81ffff Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.
Explanation: Insufficient cooling provided by fan 1.
May also be shown as 800b050a1e81ffff or 0x800b050a1e81ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 1
800b050a-1e82ffff Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.
Explanation: Insufficient cooling provided by fan 2.
May also be shown as 800b050a1e82ffff or 0x800b050a1e82ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan2