80010204-1d0affff • 80010701-1801ffff
80010204-1d0affff Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: IMM has detected the speed of a Fan (MEU Fan 5 Tach) has gone low.
May also be shown as 800102041d0affff or 0x800102041d0affff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
Reseat the failing fan indicated by the lit LED on the fan.
v
Replace Fan.
v
80010701-0c01ffff Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: An upper non-critical sensor going high has asserted.
May also be shown as 800107010c01ffff or 0x800107010c01ffff
Severity: Warning
Alert Category: Warning
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response: No action, warning of increased temperature.
80010701-1801ffff Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: An upper non-critical sensor going high has asserted.
May also be shown as 800107011801ffff or 0x800107011801ffff
Severity: Warning
Alert Category: Warning
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response: No action, warning of increased temperature.