806f040c-2581ffff • 806f0507-0302ffff
806f040c-2581ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName].
Explanation: IMM has detected that Memory has been Disabled.
May also be shown as 806f040c2581ffff or 0x806f040c2581ffff
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault, follow the suggested actions for that error event and restart
the server.
3. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM
through the Setup utility or the Advanced Settings Utility (ASU).
806f0507-0301ffff [ProcessorElementName] has a Configuration Mismatch.
Explanation: IMM has detected a Processor Configuration Mismatch on CPU 1.
May also be shown as 806f05070301ffff or 0x806f05070301ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0062
SNMP Trap ID: 40
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
806f0507-0302ffff [ProcessorElementName] has a Configuration Mismatch.
Explanation: IMM has detected a Processor Configuration Mismatch on CPU 2.
May also be shown as 806f05070302ffff or 0x806f05070302ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0062
SNMP Trap ID: 40
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
626
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3850 x5

Table of Contents