IBM X3950 X5 Problem Determination And Service Manual page 270

Types 7145, 7146, 7143, and 7191
Hide thumbs Also See for X3950 X5:
Table of Contents

Advertisement

217-800-000 • 217-900-000
217-800-000
HDD Test Aborted
Explanation: HDD Test Aborted. The test was canceled.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify that Hard drive supports self test and self test logging.
4. If the problem remains, contact your technical-support representative.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
217-900-000
HDD Test Failed
Explanation: HDD Test Failed. The hard drive self-test detected a failure.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify the firmware is at the latest level.
4. Rerun the test.
5. If the problem remains, contact your technical-support representative.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
254