806f0021-0b06ffff Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Explanation: IMM has detected a Fault in PCIe slot 3.
May also be shown as 806f00210b06ffff or 0x806f00210b06ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1. Check the I/O board LEDs.
2. Reseat the affected adapters.
3. Update the server and adapter firmware (UEFI and IMM).
4. Remove the adapter from the slot.
5. Replace the PCI Express adapter.
806f0021-0b07ffff Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Explanation: IMM has detected a Fault in PCIe slot 4.
May also be shown as 806f00210b07ffff or 0x806f00210b07ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1. Check the I/O board LEDs.
2. Reseat the affected adapters.
3. Update the server and adapter firmware (UEFI and IMM).
4. Remove the adapter from the slot.
5. Replace the PCI Express adapter.