806f010f-2201ffff The System [ComputerSystemElementName] encountered a firmware hang.
Explanation: IMM has detected a System Firmware Hang.
May also be shown as 806f010f2201ffff or 0x806f010f2201ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0186
SNMP Trap ID: 25
Automatically notify Support: No
User response:
1. Check the system- event log and correct the failures.
2. Remove the system ac power.
3. Wait 30 seconds, then restart the server.
806f0113-1701ffff A bus timeout has occurred on system [ComputerSystemElementName].
Explanation: A bus timeout has occurred.
May also be shown as 806f01131701ffff or 0x806f01131701ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0224
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1. Remove the adapter from the PCI slot that is indicated by a lit LED.
2. Replace the adapter.
3. Remove all PCI adapters.
4. (Trained service technicians only) Replace the I/O board.
806f011b-0701ffff The connector [PhysicalConnectorElementName] has encountered a configuration error.
Explanation: IMM has detected an internal connection error.
May also be shown as 806f011b0701ffff or 0x806f011b0701ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0266
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1. If the sensor name is "Planar FPGA Err",
2.
a) try to flash FPGA firmware to the latest level.
3.
b) If the error still appears with the latest FPGA firmware, Replace the CPU board.
806f010f-2201ffff • 806f011b-0701ffff
Appendix B. Integrated management module error messages
515