4.7.3

Installing modules

4.7.3.1

On the HiPath 1120

Installation Procedures
Step
1.
Turn off the power supply.
2.
Remove the system's cover
3.
Insert the module into one of the slots shown in figure 4-16.
4.
Underside: To install the LAN Interface Module or Music Module, lift the top part
(MB) of the system and use the pin bar to connect with X1 position of the LAN
Interface Module (see figure 3-24) or X2 position of the Music Module (see figure 3-
31).
5.
Top side: Interconnect the module and the MB using the flat cable/s provided, taking
care to pass it through the ferrite (see figure 4-16).
6.
Connect to the module's MDF Connectors (see figure 4-39).
7.
Reassemble the entire set.
8.
"Performing a visual inspection" on page 4-189.
9.
Turn on the power supply.
10.
Configure the required data (see "Configuring the system specifically for the client"
on page 6-205).
*
11.
Using Manager application go to: Advanced tab, > PBX Information tab, > Slot
Allocation tab;
Select the Clear All Slots checkbox;
Update the HiPath System;
Reset the HiPath System.
*
This is necessary only if you have changed the type of the modules installed in your system.