Table 2-1 Specific Limitations To System Expansion; Telephones - Siemens HiPath 1100 Service Manual

Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Extension (analog + digital)
System Telephones (KS + optiPoint)
(see "CTR-UP0/E module" on page 3-79)
Digital line with TME1/Digital line with S
External analog lines without TME1 or S
modules
Digital line (TME1) + analog line/digital line
(S0)+ analog line
*
Each system telephone (KS) that is connected occupies one analog telephone slot.
**
S
and TME1 modules cannot be used simultaneously.
0
LAN and TME1 interface modules can be used simultaneously in HiPath 1150/1190.
- HiPath 1120 : ADSL modules, SLIMC and SADSLIM module
- HiPath 1150/1190 :ADSL modules, SLIMC and SADSLIM module
*** When the maximum capacity for external lines is exceeded due to the installation of EB, S
disables external analog lines. Extension slots, however, continue to operate as usual.
Example 1: HiPath 1150
- slot 0, MB 210,
- slot 1, EB 210,
- slot 3 TME1 - 30 digital lines
EB 210 external lines will not work, but extensions will. Since the system allows for a maximum number of 32 lines, we
cannot have any additional analog line.
Example 2: HiPath 1150
- slot 0, MB 210
- slot 3 TME1 = 30 digital lines
In this case, there are 32 external lines at most available on the system. This means there is no room for an additional EB
module with an external analog line.
30 CAS/S2 digital lines + 2 MB external analog lines = 32 external lines.
If an EB 200 was installed in slot 1 or slot 2 the module would not be operable, since it would exceed the system's
maximum capacity for external lines.
Example 3: HiPath 1150
- slot 0, MB 210
- slot 3 TME1 = 10 digital lines
(WARNING: Deactivate digital line for the TME1 module and program unused digital lines on the switch as unavailable
(turn the switch off then on).
Overall, there are 12 external lines on the system. This means there are 4 additional external lines available before
reaching the maximum capacity of 16 external lines.
An additional EB 400 could be used in slot 1 or slot 2.
If an EB 800 were installed on the switch, the entire module would be inoperable since it would exceed the system's
maximum capacity for external lines.
Table 2-1
Specific limitations to system expansion
Service Manual
23
2KS
+
8 optiPoint
(4 master + 4
slave)
or
4KS
0/2
0
6
0
0/8
System expansion limitations
89
143
8 KS
8 KS
+
+
16 optiPoint
16 optiPoint
(8 master + 8
(8 master + 8
slave)
slave)
or
24 KS (CD 16
module)
30/10
45/20
16
40
32/16
45/44
or TME1 modules, the system
0
System Data
2-31