Siemens HiPath 1100 Service Manual page 74

Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Modules
Expansion modules (EB)
If an error occurs during software installation, clear the Flash memory and reinstall
the software. Follow these instructions:
Turn the PABX off
Set Switch 1 (FE) to ON
Turn the PABX on again
Wait for F and E to show on the display
Turn the PABX off
Set switch 1 (FE) to OFF again
Turn on the PABX
DIP Switch 2 (S2)
It is recommended that you do not change the DIP Switch 2 default setting.
Switch
Procedure
1
DSP - BIO
2
3
4
Battery connection
5
6
7
E1 interface impedance (E1
8
CAS access)
8
Reserved (S2 access)
Table 3-19
TME1 module, DIP Switch 2
3-74
Reserved
Reserved
MODCK2
WDI
MODCK1
Default
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 1190Hipath 1150Hipath 1120

Table of Contents