Figure 3-17 S2 Access Connection With 120 Ohm Impedance - Siemens HiPath 1100 Service Manual

Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Modules
Expansion modules (EB)
HiPath 1100
2x coax cable
S2
Figure 3-17
S2 access connection with 120 ohm impedance
Connector for TME1 module configuration
The Connector serves to link a PC or modem to a module using a serial cable (see "TME1
Serial Cable" on page 3-117). This makes it possible to program the module using the E1 Trunk
Manager tool (for E1 CAS access) or S2M Maintenance tool (S2 access).
Figure 3-18
Signal distribution on the TME1 module Connector
Warning
!
Do not touch the TME1 module's administrative serial interface Connector (X803)
without first disconnecting all analog extensions and trunk Connectors. Failure to fol-
low this procedure may expose the user to dangerous voltages.
The administrative serial interface Connector (X803) as well as all other Connectors
and interconnect cables should only be serviced by trained technical personnel.
3-72
Impedance
adapter (Bal-
un)
9-pin
Mini-DIN connector
7
9
6
3
2
1
Cable 4-wire
1 = DCD
6 = DSR
2 = RX
7 = RTS
3 = TX
8 = CTS
4 = DTR
9 = RI
5 = GND
Public Network
NT1
Service Manual