4.13.2

Model S30817-Q936-C282 - Brazil

Installation Procedures
This interface can be configured to work in pager or entrance telephone mode.
Pager mode
Step
1.
Set jumper 1 (J1) to ON and jumper 2 (J2) to OFF (see "Internal entrance telephone
with TFE interface" on page 3-103).
2.
Configure the system for entrance telephone mode and specify the extensions for
answering calls. Specify also at which extension the interface will be installed.
3.
Connect the interface to the entrance telephone extension by using contacts 1 and
2 on the X2 Connector.
4.
To activate Pager mode, lift the handset at one of the answering extensions and dial
the entrance telephone number. Once the appropriate number is dialed, the calling
extension is connected to the entrance telephone, but without voice capability.
5.
For voice capability, dial "8". The ambient sound will stop and you will be able to
leave a message. The sound will be amplified in all speakers connected to the
amplifier.
6.
To disable voice capability, dial "9". If the sound is not disabled manually, it will
timeout automatically after 15 seconds. To enable the automatic timeout, set jumper
3 (J3) to OFF.
7.
"Performing a visual inspection" on page 4-189.
8.
Configure the required data (see "Operation" on page 7-278).
The length of the cables between the X2 Connector and the PABX must not exceed
32.8 feet.
Service Manual
Installing a TFE - entrance telephone interface
Procedure
Installation
4-181