(7) Chart of image adjustment procedures
Adjusting
Item
order
Adjusting the magnification in the
auxiliary scanning direction
1
(printing adjustment)
Adjusting the center line of the MP
tray
2
(printing adjustment)
Adjusting the center line of the cas-
settes
3
(printing adjustment)
Adjusting the leading edge registra-
tion of the MP tray
4
(printing adjustment)
Adjusting the leading edge registra-
tion of the cassette
5
(printing adjustment)
Adjusting the leading edge margin
(printing adjustment)
6
Adjusting the trailing edge margin
(printing adjustment)
7
Adjusting the left and right margins
(printing adjustment)
8
Adjusting magnification of the
scanner in the main scanning direc-
9
tion
(scanning adjustment)
Adjusting magnification of the
scanner in the auxiliary scanning
direction
10
(scanning adjustment)
Image
Description
Drive motor speed adjustment
Adjusting the LSU print start timing
Adjusting the LSU print start timing
Registration motor turning on timing
(secondary paper feed start timing)
Registration motor turning on timing
(secondary paper feed start timing)
LSU illumination start timing
LSU illumination end timing
LSU illumination start/end timing
Data processing
Original scanning speed
Maintenance mode
Original
Item No.
Mode
U053
DRUM
U053 test pattern
U034
LSU OUT LEFT /MPT
U034 test pattern
LSU OUT LEFT /
DUPLEX
U034
LSU OUT LEFT /
U034 test pattern
CASSETTE
U034
LSU OUT TOP /MPT
U034 test pattern
LSU OUT TOP /
DUPLEX
U034
LSU OUT TOP /
U034 test pattern
CASSETTE
U402
LEAD
U402 test pattern
U402
TRAIL
U402 test pattern
U402
A MARGIN
U402 test pattern
C MARGIN
U065
MAIN SCAN
Test chart
U070
MAIN SCAN(CIS)
U065
SUB SCAN
Test chart
U070
SUB SCAN (F)
SUB SCAN (B)
SUB SCAN (CIS)
2-4-19
Page
Remarks
P.1-3-42
P.1-3-37
To make an adjustment for duplex copying, select
LSU OUT LEFT /DUPLEX.
P.1-3-37
P.1-3-37
To make an adjustment for duplex copying, select
LSU OUT TOP /DUPLEX.
PAPER WIDTH 218mm or more
P.1-3-37
PAPER WIDTH 218mm or more
P.1-3-129
P.1-3-129
P.1-3-129
P.1-3-44
U065: For copying an original placed on the platen.
U070: For copying originals from the DP.
P.1-3-44
U065: For copying an original placed on the platen.
P.1-3-49
U070: For copying originals from the DP.
To make an adjustment for second side: select SUB
SCAN(B) :Mechanism reversal model
To make an adjustment for second side: select SUB
SCAN(B) :Double-sided simultaneous reading model
2NP

Hide quick links:

Advertisement

Table of Contents
loading