Connector
Pin
B5
MISENS
YC6
Connected to
B6
HVU1_REM
high voltage
PWB
B7
DC_SLV_BK
B8
DC_MAG_M
B9
DC_MAG_BK
B10 DC_SLV_M
B11 DC_MAIN_CO
NT_BK
B12 DC_MAIN_CO
NT_M
B13 AC_MAIN_CO
NT_BK
B14 HVU_CLK_BK
B15 HVU_CLK_M
B16 24VIL3
B17 24VIL3
1
GND
YC8
Connected to
2
TMPDATA
temperature
3
HUM_CLK1
sensor
4
HUM_CLK2
5
HUMDATA
1
GND
YC7
Connected to
2
T1_CONT_BK
high voltage
PWB sub
3
T1_CONT_C
4
CL_CONT
5
HVU2_REM
6
T1_CONT_Y
7
T1_CONT_M
8
24VIL3
Signal
I/O
I
Analog
O
0/10 to 24 V DC
(pulse)
O
Analog
O
Analog
O
Analog
O
Analog
O
Analog
O
Analog
O
Analog
O
0/10 V DC (pulse)
O
0/10 V DC (pulse)
O
24 V DC
O
24 V DC
-
-
I
Analog
O
0/3.3 V DC(pulse)
O
0/3.3 V DC(pulse)
I
Analog
-
-
O
Analog
O
Analog
O
Analog
O
0/10 to 24 V DC
(pulse)
O
Analog
O
Analog
O
24 V DC
Voltage
Chager roller AC current signal
Developer bias remote signal
Developer sleeve roller bias control
voltage (black)
Developer magnet roller bias control
voltage (magenta)
Developer magnet roller bias control
voltage (black)
Developer sleeve roller bias control
voltage (magenta)
Chager roller control voltage (black)
Chager roller control voltage (magenta)
Developer AC bias control voltage (black)
Developer bias clock signal (black)
Developer bias clock signal (magenta)
24 V DC power output to HVPWB
24 V DC power output to HVPWB
Ground
TEMS detection voltage (temperature)
TEMSClock signal
TEMSClock signal
TEMS detection voltage (humidity)
Ground
Primary transfer bias control voltage
(black)
Primary transfer bias control voltage
(magenta)
Cleaning bias control voltage
Transfer bias remote signal
Primary transfer bias control voltage
(yellow)
Primary transfer bias control voltage
(cyan)
24 V DC power output to HVPWB-S
2-3-15
Description