Kyocera TASKalfa 2551ci Service Manual page 242

Hide thumbs Also See for TASKalfa 2551ci:
Table of Contents

Advertisement

Item No.
U425
Setting: [Adjust Original]
* : This setting is usually unnecessary.
1. Measure the distance from the left edge to the black belt (a) of the original at A, B and C.
Measurement procedure
1) Measure the distance from the edge to the black belt (a) of the original at A (30 mm from
the leading edge), B (148.5 mm from the leading edge) and C (267 mm from the leading
edge), respectively.
2) Apply the following formula for the values obtained: ((A + C) / 2 + B) / 2
2. Enter the values solved using the +/- keys or numeric keys in [Lead].
3. Press the start key. The value is set.
4. Measure the distance from the leading edge to the black belt (b) of the original at D, E and F.
Measurement procedure
1) Measure the distance from the edge to the black belt (b) of the original at D (35 mm from
the left edge), E (110 mm from the left edge) and F (185 mm from the left edge), respec-
tively.
2) Apply the following formula for the values obtained: ((D + F) / 2 + E) / 2
5. Enter the values solved using the +/- keys or numeric keys in [Main Scan].
6. Press the start key. The value is set.
7. Measure the length (G) from the edge of the black belt (a) to edge of N475 of the original.
8. Enter the measured value using the +/- keys or numeric keys in [Sub Scan].
9. Press the start key. The value is set.
Leading edge
Left edge
35 mm
110 mm
185 mm
30 mm
A
Black
belt (a)
D
Black
belt (b)
E
F
Original for adjustment (P/N: 302FZ56990)
Description
148.5 mm
B
G
Figure 1-3-42
1-3-145
267 mm
C
Black
belt (c)
[Lead] =
((A + C) / 2 + B) / 2
[Main Scan] =
((D + F) / 2 + E) / 2
[Sub Scan] = G
2NP-2