Kyocera TASKalfa 2551ci Service Manual page 527

Hide thumbs Also See for TASKalfa 2551ci:
Table of Contents

Advertisement

Connector
Pin
1
24V1
YC18
Connected to
2
IH_FAN1_RE
IH fan motor
M
3
IH_FAN1_AL
M
1
24V1F3
YC19
Connected to
2
IH_FAN2_RE
containaer/IH
M
coil fan
3
IH_FAN2_AL
motor,
M
developer
4
24VIL3
fan motor1
5
DLP_FAN_RE
and eject
M
fanmotor
6
24V1
7
CON_FAN_R
EM
1
24V1F1
YC20
Connected to
2
TN_MOT_RE
toner motor
M_Y
Y/C/M/K
3
24V1F1
4
TN_MOT_RE
M_C
5
24V1F1
6
TN_MOT_RE
M_M
7
24V1F1
8
TN_MOT_RE
M_BK
1
EJE_SOL_RE
YC21
M
Connected to
2
24V1F2
feed sift
3
EJE_MOT_/B
solenoid,
4
EJE_MOT_/A
eject motor,
5
EJE_MOT_B
paper full
sensor, job
6
EJE_MOT_A
paper full
7
3.3V1_A
sensor
8
GND
Signal
I/O
O
24 V DC
O
0/24 V DC
I
0/3.3 V DC
O
24 V DC
O
0/24 V DC
I
0/3.3 V DC
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
3.3 V DC
-
-
Voltage
24 V DC power output to IHFM
IHFM: On/Off
IHFM alarm signal
24 V DC power output to C/IHCFM
C/IHCFM: On/Off
C/IHCFM alarm signal
24 V DC power output to DEVFM1
DEVFM1: On/Off
24 V DC power output to EFM
EFM: On/Off
24 V DC power output to TM-Y
TM-Y: On/Off
24 V DC power output to TM-C
TM-C: On/Off
24 V DC power output to TM-M
TM-M: On/Off
24 V DC power output to TM-K
TM-K: On/Off
FSSOL: On/Off
24 V DC power output to FSSOL
EM drive control signal
EM drive control signal
EM drive control signal
EM drive control signal
3.3 V DC power output to PFS
Ground
2-3-20
Description
2NP

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents