4. Insert the locating ball of each scanner
wires into the hole in the respective
scanner wire drum and wind the scan-
ner wire three turns inward and four
turns outward.
With the locating ball as the reference
point, wind the shorter end of each of
the wires outward.
5. Secure the scanner wires using the
scanner wire stoppers.
6. Refit the scanner wire drum shaft to the
scanner unit.
7. Insert the two frame securing tools into
the positioning holes at the front and
rear of the scanner unit to fix the mirror
frame 2 in position.
Locating
ball
Scanner wire drums
Frame securing tool
1-5-35
Scanner wire
stoppers
Three turns
inward
Four turns
outward
Figure 1-5-62
Frame securing tool
Mirror frame 2
Figure 1-5-63
2NP-6
Locating
ball