176 – Remote Operation
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
184 – Open After Alarm
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
200 - Zone Follower - Single Zone
01 – True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
02 – Timed Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until the zone is restored.
04 – Latching
ON: output remains latched until a valid access code is entered or a valid Prox tag is presented.
OFF: output follows the setting of the Timed Output attribute.
05 – Follow Alarm
ON: output is activated on zone alarm and stays active until the bell is turned off. See table for operation with bits 2
and 4.
OFF: output is activated on zone opening and deactivated when zone is closed.
Timed Output Latching Follow Alarm PGM Output
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
201 – 216 Zone Follower Zones 1-128
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
02 – Timed Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until an access code has been entered.
Section 6: Programming
OFF
ON upon zone opening (including tamper and fault), OFF upon zone closing
ON
ON upon zone alarm, OFF upon bell cut-off or alarm silenced
OFF
ON upon zone opening, OFF upon valid code
ON
ON upon zone alarm, OFF upon valid code
OFF
ON upon zone opening, OFF upon PGM timer expires
ON
ON upon zone alarm, OFF upon PGM timer expires
OFF
ON upon zone opening, OFF upon valid code
ON
ON upon zone alarm, OFF upon valid code