DSC HS2128 Reference Manual page 132

Powerseries neo alarm controller
Hide thumbs Also See for HS2128:
Table of Contents

Advertisement

[851] Alternate Communicator Programming
See the alternate communicator installation manual for programming instructions.
[860] Display Keypad Slot Number
The 2-digit slot number of the keypad being used is displayed in this read only section.
[861]-[876] Keypad Programming
Use section [861] to [876] to configure keypads 1 to 16. For information on keypad programming, refer to the installation
sheet supplied with the keypad.
EN
Note: For EN50131 compliant installations [861][021] options 1 and 2 must be disabled.
[899] Template Programming
Template programming allows quick programming of the minimum functions required for basic operation. This section is
used to view current template programming options and to define certain system parameters. Press the (#) key to accept the
displayed value and advance to the next option. The following options are available:
5-digit Template Code: Displays the current 5-digit template programming code (default: 00000). Each digit in the
l
code selects a set of pre-defined programming options, as described below:
Digit 1 - zone 1-8 definition options
l
Digit 2 - system EOL options
l
Digit 3 - alarm controller communications options
l
Digit 4 - reporting code configurations
l
Digit 5 - DLS connection options
l
Central Station Telephone Number: The phone number used to contact the central monitoring station (32 character
l
limit).
Central Station Account Code: The account code used in programming section [310]. This is a 4 or 6-digit entry.
l
Partition Account Code: Used to identify partition-specific events. All 4 digits must be entered in order to complete the
l
entry.
This account code is entered into programming section [310][001].
l
DLS Access Code: The 6-digit DLS access code used in programming section [403].
l
Partition 1 Entry Delay: The 3-digit entry delay duration for partition 1, in seconds, used in programming [005][001]
l
option 1.
Partition 1 Exit Delay: The 3-digit exit delay duration for partition 1, in seconds, used in programming section [005]
l
[001] option 3.
Installer Code: The 4, 6 or 8-digit installer access code used in programming section [006][001].
l
For more information on template programming, see "Template Programming Tables" on page 223.
6.3.19 Systems Information
[900] System Information
[000] – Control Panel Version
This read-only section contains the model number, software version, hardware revision, of the alarm controller. For example,
an entry of 1234 is read as version 12.34.
[001]-[524] – Module Information
This read-only section is used to view the model number, software version, and hardware revision information of the mod-
ules enrolled on the alarm system.
To view information for a specific module, scroll to the corresponding section:
Section 6: Programming
- 132 -