[302] Panel Events 2
1/2 – Bell Circuit Trouble/Restore
This reporting code is transmitted when a bell trouble condition occurs or is restored on the system.This reporting code is
sent to the System Maintenance call direction group.
3/4 – Telephone Line Trouble and Restore
This reporting code is transmitted when an alarm controller TLM trouble occurs or is restored. The TLM trouble is com-
municated over an unaffected communication path if available.
This reporting code is sent to the System Maintenance call direction group.
5/6 – Auxiliary Power Supply Trouble/Restore
This reporting code is transmitted when an auxiliary voltage supply trouble occurs or is restored. This reporting code is sent
to the System Maintenance call direction group.
Note: When the electronic fuse built in to the auxiliary power supply is tripped due to a short or high current draw, the alarm
system must be powered down then back up to reset the fuse.
[305] Panel Events 5
3/4 – PGM 2 2-Wire Trouble/Restore
This reporting code is transmitted when a trouble condition on PGM 2, configured as two-wire smoke, occurs or is restored.
This reporting code is sent to the System Maintenance call direction group.
[311] Maintenance Events 1
1/2 – RF Jam Trouble/Restore
Sent when RF jam troubles occur/are restored. The following events cause RF jam troubles:
Wireless repeater jamming
l
RF jam
l
3/4 – Fire Trouble/Restore
Sent when a low sensitivity, tamper or internal fault condition/restore is detected on a wireless smoke detector.
5 – Cold Start
Sent when power is restored to the alarm system after total power failure. The code is sent after 2 minutes to allow the alarm
controller to stabilize.
6 – Delinquency
When the Delinquency option is off (page 116), this code is transmitted if the alarm system has not been armed for the num-
ber of days programmed in the Delinquency Transmission Delay (page 122).
When the Delinquency option is on, this code is transmitted when no zone activity has been detected on the system for the
number of hours programmed in Delinquency Transmission Delay.
7 – Self Test Trouble
Sent when a self test trouble occurs for an outdoor PIR.
8 – Self Test Trouble Restore
Sent when a self test trouble has been restored for an outdoor PIR.
[312] Maintenance Events 2
1/2 – Installer Lead In/ Lead Out
The Installer Lead In and Lead Out reporting codes are sent when the alarm system enters and exits Installer Programming
respectively.
When Installer Programming is automatically exited after PC-Link is activated, the Installer Lead Out event is not com-
municated until after the DLS session is complete.