12 – RF Delinquency
ON: activates if any of the following RF delinquency troubles is detected:
zone 001 – 128
l
keypad 01 – 16
l
siren 01 – 16
l
repeater 01 – 08
l
OFF – does not activate if an RF delinquency condition is present.
13 – Module Supervisory
ON – activates if any of the following module supervisory troubles is detected:
HSM2HOST
l
keypad 01 – 16
l
zone expander 01 – 15
l
HSM2204 1 – 4
l
HSM2300 1 – 4
l
HSM2208 01 – 16
l
OFF – does not activate if a module supervisory trouble is detected.
14 – Module Tamper
ON – activates if any of the following module tamper conditions is present:
HSM2HOST
l
Keypad 01 – 16
l
Zone expander 01 – 15
l
HSM2204 1 – 4
l
HSM2300 1 – 4
l
HSM2208 01 – 16 tamper troubles
l
OFF – does not activate if a module tamper condition is present.
15 – Communications
ON – activates if any of the following communications conditions is present:
TLM trouble
l
FTC receiver 1 – 4
l
SIM Lock trouble
l
Cellular Trouble
l
Ethernet Trouble
l
Receiver 1 – 4 absent
l
Receiver 1 – 4 supervision trouble
l
SMS Configuration trouble
l
Alt comm. Fault.
l
OFF – does not activate if a communications trouble condition is present.
16 – Not Networked
ON – activates if any of the following not networked conditions is present:
Zone 001 – 128
l
Keypad 01 – 16
l
Siren 01 – 16
l
Repeater 01 – 08
l
User 01 – 1000 (wireless keys) not networked troubles
l